An Alkali-Metal Thermal Converter Coupled to a Fission Heat Source for an Outer-Planet Orbiter: Efficiency Between Its Temperatures, Radiator Sizing and Specific Mass

This paper presents a design study of a system whose operating principle is Alkali-metal thermal-to-electric conversion (sodium heat-pipe AMTEC) from fission heat. The sizing is computed from stated assumptions, with every headline quantity produced by the deposited calculation script. The headline results are: electrical kW = 25.5; carnot = 0.545; radiator m2 = 23; specific power W per kg = 22.1. The study is simulated and computed, not measured, and the design is labelled SIMULATED, NOT MEASURED. Where the computed outcome is unfavourable to the concept, that outcome is stated as the result rather than softened: the purpose of the study is to establish, from the governing relations, what a system of this kind can deliver at the stated distance, temperature, or scale, what it costs in mass, area or power, and which assumption controls the answer.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-12
DOI
https://doi.org/10.5281/zenodo.24169103
Citations
1
Primary Topic
Advanced Energy Technologies and Civil Engineering Innovations
Type
article
Field-Weighted Citation Impact
3.09
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

An Alkali-Metal Thermal Converter Coupled to a Fission Heat Source for an Outer-Planet Orbiter: Efficiency Between Its Temperatures, Radiator Sizing and Specific Mass

William Alexander Aldred
1 citations
Zenodo (CERN European Organization for Nuclear Research)
Advanced Energy Technologies and Civil Engineering Innovations
3.09
article

An Alkali-Metal Thermal Converter Coupled to a Fission Heat Source for an Outer-Planet Orbiter: Efficiency Between Its Temperatures, Radiator Sizing and Specific Mass

William Alexander Aldred
article en
1 citations

Abstract

This paper presents a design study of a system whose operating principle is Alkali-metal thermal-to-electric conversion (sodium heat-pipe AMTEC) from fission heat. The sizing is computed from stated assumptions, with every headline quantity produced by the deposited calculation script. The headline results are: electrical kW = 25.5; carnot = 0.545; radiator m2 = 23; specific power W per kg = 22.1. The study is simulated and computed, not measured, and the design is labelled SIMULATED, NOT MEASURED. Where the computed outcome is unfavourable to the concept, that outcome is stated as the result rather than softened: the purpose of the study is to establish, from the governing relations, what a system of this kind can deliver at the stated distance, temperature, or scale, what it costs in mass, area or power, and which assumption controls the answer.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy
Openalex Percentile: Top 17%
Advanced Energy Technologies and Civil Engineering Innovations
3.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon