Measuring Redshift From Tides Alone: The Tidal Siren Method Quantified

This paper asks a single question and computes its answer. The tidal deformability of a neutron star depends on its rest-frame mass, so a measured detector-frame mass plus a tidal measurement yields a redshift with no counterpart; what precision follows from stated tidal measurement errors? Working in a flat LambdaCDM background and carrying the bounce-frame density ceiling explicitly — the Aldred Limit, rho_A = rho_Pl (m/m_Pl)^2/(8 pi C), with the neutron branch at 9.72e+54 g per cubic centimetre — the calculation gives the headline values w05 = 0.28, w015 = 0.10, med = 0.30, rhoA = 9.72e+54. At present-day tidal precisions the redshift interval is broad, of order the redshift itself; at the fifteen per cent tidal precision expected from third-generation detectors the interval narrows to a cosmologically useful width. The median stays centred on the input redshift, so the method is unbiased in this model. Every number reported here comes from the deposited computation script, which states its assumptions in full. This study is simulated and computed from stated assumptions and published catalogue values; it is not a measurement.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-12
DOI
https://doi.org/10.5281/zenodo.24152023
Primary Topic
Pulsars and Gravitational Waves Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Measuring Redshift From Tides Alone: The Tidal Siren Method Quantified

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Pulsars and Gravitational Waves Research
article

Measuring Redshift From Tides Alone: The Tidal Siren Method Quantified

William Alexander Aldred
article en

Abstract

This paper asks a single question and computes its answer. The tidal deformability of a neutron star depends on its rest-frame mass, so a measured detector-frame mass plus a tidal measurement yields a redshift with no counterpart; what precision follows from stated tidal measurement errors? Working in a flat LambdaCDM background and carrying the bounce-frame density ceiling explicitly — the Aldred Limit, rho_A = rho_Pl (m/m_Pl)^2/(8 pi C), with the neutron branch at 9.72e+54 g per cubic centimetre — the calculation gives the headline values w05 = 0.28, w015 = 0.10, med = 0.30, rhoA = 9.72e+54. At present-day tidal precisions the redshift interval is broad, of order the redshift itself; at the fifteen per cent tidal precision expected from third-generation detectors the interval narrows to a cosmologically useful width. The median stays centred on the input redshift, so the method is unbiased in this model. Every number reported here comes from the deposited computation script, which states its assumptions in full. This study is simulated and computed from stated assumptions and published catalogue values; it is not a measurement.

Zenodo (CERN European Organization for Nuclear Research)
Pulsars and Gravitational Waves Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon