Platform Adaptation During Transition to New Robotic Systems: Learning Curves Across the Da Vinci® X™, Versius®, and Hugo™ RAS Platforms for Robot-Assisted Hysterectomy

Abstract Purpose: To characterize adaptation when an experienced robotic surgical team transitioned from the Da Vinci® X™ platform to the Versius® and Hugo™ RAS systems for robot-assisted hysterectomy. Methods: This secondary analysis of the prospective, single-center COMPAR-HYST study included 144 analyzed procedures (Da Vinci® X™, n = 50; Hugo™ RAS, n = 48; Versius®, n = 46). Draping, docking, hysterectomy, colporrhaphy, and undocking times were evaluated. Platform-specific adaptation was assessed using risk-adjusted cumulative sum curves with segmented regression, and user experience was evaluated prospectively using standardized questionnaires. Results: Setup-related times differed across platforms, whereas hysterectomy (p = 0.173) and colporrhaphy (p = 0.087) times did not. Risk-adjusted cumulative sum analyses showed phase-specific patterns. Significant transitions occurred for draping with Hugo™ RAS (15 procedures) and Versius® (38.9), docking with Da Vinci® X™ (4) and Versius® (6.4), hysterectomy with Da Vinci® X™ (32) and Versius® (13), colporrhaphy with all three platforms (5.3, 24.2, and 33.4, respectively), and undocking with all three platforms (29, 15.1, and 7.3, respectively). User-experience ratings broadly paralleled these objective patterns. Conclusions: Adaptation was not uniform across the components of robot-assisted hysterectomy. Setup-related phases and vaginal cuff closure showed the most evident platform-specific patterns, whereas core console-based performance appeared more transferable. These findings may support phase-specific training when new robotic platforms are introduced. Trial registration: ClinicalTrials.gov NCT06138197; registered 15/11/2023.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-12
DOI
https://doi.org/10.21203/rs.3.rs-10989024/v1
Primary Topic
Surgical Simulation and Training
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Platform Adaptation During Transition to New Robotic Systems: Learning Curves Across the Da Vinci® X™, Versius®, and Hugo™ RAS Platforms for Robot-Assisted Hysterectomy

Stefano Uccella, Mariachiara Bosco, Rosa Maria Laterza, Riccardo Vizza et al.
Research Square
Surgical Simulation and Training
preprint

Platform Adaptation During Transition to New Robotic Systems: Learning Curves Across the Da Vinci® X™, Versius®, and Hugo™ RAS Platforms for Robot-Assisted Hysterectomy

Stefano Uccella, Mariachiara Bosco, Rosa Maria Laterza, Riccardo Vizza, Simone Giacopuzzi, Filippo Sartori, Liliana Galli, Marianna Donini, Simone Garzon, Biancamaria Del Prete, Pier Carlo Zorzato
preprint en

Abstract

Abstract Purpose: To characterize adaptation when an experienced robotic surgical team transitioned from the Da Vinci® X™ platform to the Versius® and Hugo™ RAS systems for robot-assisted hysterectomy. Methods: This secondary analysis of the prospective, single-center COMPAR-HYST study included 144 analyzed procedures (Da Vinci® X™, n = 50; Hugo™ RAS, n = 48; Versius®, n = 46). Draping, docking, hysterectomy, colporrhaphy, and undocking times were evaluated. Platform-specific adaptation was assessed using risk-adjusted cumulative sum curves with segmented regression, and user experience was evaluated prospectively using standardized questionnaires. Results: Setup-related times differed across platforms, whereas hysterectomy (p = 0.173) and colporrhaphy (p = 0.087) times did not. Risk-adjusted cumulative sum analyses showed phase-specific patterns. Significant transitions occurred for draping with Hugo™ RAS (15 procedures) and Versius® (38.9), docking with Da Vinci® X™ (4) and Versius® (6.4), hysterectomy with Da Vinci® X™ (32) and Versius® (13), colporrhaphy with all three platforms (5.3, 24.2, and 33.4, respectively), and undocking with all three platforms (29, 15.1, and 7.3, respectively). User-experience ratings broadly paralleled these objective patterns. Conclusions: Adaptation was not uniform across the components of robot-assisted hysterectomy. Setup-related phases and vaginal cuff closure showed the most evident platform-specific patterns, whereas core console-based performance appeared more transferable. These findings may support phase-specific training when new robotic platforms are introduced. Trial registration: ClinicalTrials.gov NCT06138197; registered 15/11/2023.

Research Square
University of Verona (IT)
Good health and well-being
Surgical Simulation and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon