Trap characteristics and space charge injection in XLPE cable insulation under repetitive damped AC voltage

Abstract Damped AC voltage (DAC) has been widely used for on-site partial discharge detection of XLPE power cables, whereas the effect of its DC charging stage on cable insulation remains unclear. In this work, XLPE specimens were subjected to repeated DAC voltage applications, and the resulting physicochemical properties, trap characteristics and space-charge behavior were investigated by Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), thermally stimulated depolarization current (TSDC), DC conductivity and pulsed electroacoustic (PEA) measurements. The results show that no obvious chemical change or crystallinity variation occurs after 500 DAC applications. However, at this stage, the trap density increases from 3.51×1015 m-3 to 1.06 × 1016 m-3 (by approximately three times), with space charge evolving from interfacial accumulation to full penetration across the sample, and the electric field distortion ratio rising from 19.3% to 47.6%. These findings suggest a possible transition from interface-dominated to synergistic interface–bulk charge interaction in XLPE under repetitive DAC stress, which may represent an important stage in the electrical aging process of this material.

Authors

Institutions

Publication Details

Journal
Materials Research Express
Published
2026-11-12
DOI
https://doi.org/10.1088/2053-1591/aec1c5
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Trap characteristics and space charge injection in XLPE cable insulation under repetitive damped AC voltage

Yongbin Liu, Nan Cao, Bin Gu, Yuantao Zhao et al.
Materials Research Express
High voltage insulation and dielectric phenomena
article

Trap characteristics and space charge injection in XLPE cable insulation under repetitive damped AC voltage

Yongbin Liu, Nan Cao, Bin Gu, Yuantao Zhao, Mingyue Liu
article en

Abstract

Abstract Damped AC voltage (DAC) has been widely used for on-site partial discharge detection of XLPE power cables, whereas the effect of its DC charging stage on cable insulation remains unclear. In this work, XLPE specimens were subjected to repeated DAC voltage applications, and the resulting physicochemical properties, trap characteristics and space-charge behavior were investigated by Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), thermally stimulated depolarization current (TSDC), DC conductivity and pulsed electroacoustic (PEA) measurements. The results show that no obvious chemical change or crystallinity variation occurs after 500 DAC applications. However, at this stage, the trap density increases from 3.51×1015 m-3 to 1.06 × 1016 m-3 (by approximately three times), with space charge evolving from interfacial accumulation to full penetration across the sample, and the electric field distortion ratio rising from 19.3% to 47.6%. These findings suggest a possible transition from interface-dominated to synergistic interface–bulk charge interaction in XLPE under repetitive DAC stress, which may represent an important stage in the electrical aging process of this material.

Materials Research Express
Xi'an Jiaotong University (CN)
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon