Optimization of PEG precipitation for macroprolactinemia screening

OBJECTIVES: To determine whether 20 % or 25 % polyethylene glycol 6000 (PEG) is more suitable for macroprolactinemia screening and to investigate methodological factors affecting PEG precipitation. METHODS: Serum samples from five individuals with macroprolactinemia and five hyperprolactinemic controls were analyzed. Gel filtration chromatography quantified the precipitation of individual prolactin (PRL) molecular forms. Nonspecific monomeric PRL precipitation was assessed using an artificial serum matrix. Incubation time, temperature, pH, and PEG solvent were also investigated. RESULTS: In the artificial serum matrix, monomeric PRL precipitation was significantly lower with 20 % than with 25 % PEG (29.3 ± 5.0 % vs. 39.2 ± 6.2 %; p=0.0053). In macroprolactinemic sera, both PEG concentrations precipitated more than 90 % of macroPRL and big PRL, with no significant differences between the two concentrations. However, monomeric PRL precipitation was significantly lower with 20 % than with 25 % PEG (28.5 ± 9.4 % vs. 39.8 ± 11.0 %; p=0.0033). Despite this difference, the proportions of monomeric PRL in the PEG precipitates differed by only 3.0 percentage points. Incubation time and temperature had limited effects on the signal-to-noise ratio. Increasing pH reduced precipitation rates without substantially altering this ratio. A 0.1 mol/L phosphate buffer at pH 7.0 maintained higher precipitation rates in alkalinized, long-term-stored serum samples. CONCLUSIONS: Both PEG concentrations efficiently precipitated macroPRL and big PRL, whereas 20 % PEG reduced nonspecific monomeric PRL precipitation and may be preferable for macroprolactinemia screening. A 0.1 mol/L phosphate buffer at pH 7.0 may be advantageous as a PEG solvent for analyzing alkalinized, long-term-stored serum samples.

Authors

Institutions

Publication Details

Journal
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2026-11-12
DOI
https://doi.org/10.1515/cclm-2026-1812
Primary Topic
Pituitary Gland Disorders and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Optimization of PEG precipitation for macroprolactinemia screening

Norito Nishiyama, 充浩 森田, Takanori Saito, Naoki Hattori
Clinical Chemistry and Laboratory Medicine (CCLM)
Pituitary Gland Disorders and Treatments
article

Optimization of PEG precipitation for macroprolactinemia screening

Norito Nishiyama, 充浩 森田, Takanori Saito, Naoki Hattori
article en

Abstract

OBJECTIVES: To determine whether 20 % or 25 % polyethylene glycol 6000 (PEG) is more suitable for macroprolactinemia screening and to investigate methodological factors affecting PEG precipitation. METHODS: Serum samples from five individuals with macroprolactinemia and five hyperprolactinemic controls were analyzed. Gel filtration chromatography quantified the precipitation of individual prolactin (PRL) molecular forms. Nonspecific monomeric PRL precipitation was assessed using an artificial serum matrix. Incubation time, temperature, pH, and PEG solvent were also investigated. RESULTS: In the artificial serum matrix, monomeric PRL precipitation was significantly lower with 20 % than with 25 % PEG (29.3 ± 5.0 % vs. 39.2 ± 6.2 %; p=0.0053). In macroprolactinemic sera, both PEG concentrations precipitated more than 90 % of macroPRL and big PRL, with no significant differences between the two concentrations. However, monomeric PRL precipitation was significantly lower with 20 % than with 25 % PEG (28.5 ± 9.4 % vs. 39.8 ± 11.0 %; p=0.0033). Despite this difference, the proportions of monomeric PRL in the PEG precipitates differed by only 3.0 percentage points. Incubation time and temperature had limited effects on the signal-to-noise ratio. Increasing pH reduced precipitation rates without substantially altering this ratio. A 0.1 mol/L phosphate buffer at pH 7.0 maintained higher precipitation rates in alkalinized, long-term-stored serum samples. CONCLUSIONS: Both PEG concentrations efficiently precipitated macroPRL and big PRL, whereas 20 % PEG reduced nonspecific monomeric PRL precipitation and may be preferable for macroprolactinemia screening. A 0.1 mol/L phosphate buffer at pH 7.0 may be advantageous as a PEG solvent for analyzing alkalinized, long-term-stored serum samples.

Clinical Chemistry and Laboratory Medicine (CCLM)
Kansai Medical University (JP), Kansai Medical University Hospital (JP)
Good health and well-being
Pituitary Gland Disorders and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon