Self-Sensing Piezoelectric Microcantilever Mass Sensor Based on Graphene Platelet- Reinforced Composite: Performance in Air and Liquid

Abstract Resonant microcantilevers (MCs) are used for mass sensing, but their performance depends on the beam material and the surrounding medium. This paper presents a study of a self-actuating, self-sensing piezoelectric MC with a non-uniform geometry and a multilayer graphene platelet-reinforced composite (GPLRC) host structure. The model, based on Euler–Bernoulli beam theory and Hamilton’s principle, includes the hydrodynamic loading of the liquid and uses the output current of the piezoelectric layer as the sensing signal. It was validated against experimental data in air and in water–glycerol mixtures, with deviations of about 2% in frequency in air and below 5.1% in liquids. The relative current change ΔI/I caused by a 20 ng nanoparticle was evaluated for four GPL distribution patterns, three polymer matrices (epoxy, polyamide 6, and polypropylene), and different GPL contents and liquids. In air, ΔI/I reaches about 22% under the baseline conditions, whereas in water it is about one order of magnitude smaller (1.1–2.4%). The O-GPLRC pattern gave the highest sensitivity in both media, while the matrix had only a small effect. A Sobol sensitivity analysis showed that the GPL width and thickness dominate the variance of ΔI/I, whereas the GPL length contributes only 2–5%.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-12
DOI
https://doi.org/10.21203/rs.3.rs-11502571/v1
Primary Topic
Advanced MEMS and NEMS Technologies
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Self-Sensing Piezoelectric Microcantilever Mass Sensor Based on Graphene Platelet- Reinforced Composite: Performance in Air and Liquid

Reza Ghaderi
1 links
Research Square
Advanced MEMS and NEMS Technologies
preprint

Self-Sensing Piezoelectric Microcantilever Mass Sensor Based on Graphene Platelet- Reinforced Composite: Performance in Air and Liquid

Reza Ghaderi
preprint en

Abstract

Abstract Resonant microcantilevers (MCs) are used for mass sensing, but their performance depends on the beam material and the surrounding medium. This paper presents a study of a self-actuating, self-sensing piezoelectric MC with a non-uniform geometry and a multilayer graphene platelet-reinforced composite (GPLRC) host structure. The model, based on Euler–Bernoulli beam theory and Hamilton’s principle, includes the hydrodynamic loading of the liquid and uses the output current of the piezoelectric layer as the sensing signal. It was validated against experimental data in air and in water–glycerol mixtures, with deviations of about 2% in frequency in air and below 5.1% in liquids. The relative current change ΔI/I caused by a 20 ng nanoparticle was evaluated for four GPL distribution patterns, three polymer matrices (epoxy, polyamide 6, and polypropylene), and different GPL contents and liquids. In air, ΔI/I reaches about 22% under the baseline conditions, whereas in water it is about one order of magnitude smaller (1.1–2.4%). The O-GPLRC pattern gave the highest sensitivity in both media, while the matrix had only a small effect. A Sobol sensitivity analysis showed that the GPL width and thickness dominate the variance of ΔI/I, whereas the GPL length contributes only 2–5%.

Research Square
Islamic Azad University, Tehran (IR)
Advanced MEMS and NEMS Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon