Dynamic accommodative stress testing for early detection of anterior segment deformation patterns in subclinical keratoconus
To investigate dynamic anterior segment alterations during accommodative effort in subclinical keratoconus (SKC) using combined Scheimpflug-Placido imaging and anterior segment optical coherence tomography (AS-OCT), and to establish a dynamic stress test for early ectasia detection. In this prospective diagnostic accuracy study, 180 participants (one eye each) were allocated to three age-matched groups: bilateral subclinical keratoconus (SKC, n = 60), very asymmetric ectasia with clinically unaffected fellow eyes (VAE-NT, n = 60) and healthy controls ( n = 60). Anterior segment imaging was performed under standardised mesopic conditions at accommodative stimuli of 0, 3 and 6 D delivered through a Badal optometer. Primary outcomes were the accommodation-induced changes in anterior chamber depth (ΔACD) and maximum keratometry (ΔKmax). Two composite indices, the Dynamic Ectasia Index (DEI) and the Corneal Thickness Redistribution Index (CTRI), were derived from the present dataset after data collection and were not prespecified. At 6 D, SKC eyes deformed more than controls in every primary outcome: ΔACD − 0.114 ± 0.021 mm versus − 0.069 ± 0.015 mm, and inferotemporal curvature change 1.76 ± 0.27 D versus 0.66 ± 0.17 D (both p < 0.001). DEI separated SKC from control eyes with 98.3% sensitivity and 96.7% specificity (AUC 0.995, 95% CI 0.989–1.000), and the bivariate DEI + CTRI rule with 96.7% and 98.3%. The Belin/Ambrósio D-index reached an AUC of 1.000, but because its thresholds defined group eligibility this separation is an artefact of the sampling frame and not a measure of performance. All estimates were derived and evaluated in the same dataset and are therefore optimistic. Accommodative stress testing reveals anterior segment deformation patterns that distinguish SKC eyes from healthy controls. DEI and CTRI provide an empirically derived screening framework and should be interpreted as screening composites rather than biomechanical parameters. External validation in independent cohorts is required before clinical use.
Authors
- Yusuf Evcimen (ORCID: https://orcid.org/0000-0002-9934-2881)
- Burhan Başkan (ORCID: https://orcid.org/0000-0002-2481-9892)
Institutions
- Education Training And Research (US)
- Sağlık Bilimleri Üniversitesi (TR)
Publication Details
- Journal
- Scientific Reports
- Published
- 2026-11-12
- DOI
- https://doi.org/10.1038/s41598-026-79398-x
- Primary Topic
- Corneal surgery and disorders
- Type
- article
- Field-Weighted Citation Impact
- 0.00