Transferability of the classic volumetric myocardial contrast echocardiography formula to constant-flow Langendorff-perfused rabbit hearts

The classic volumetric myocardial contrast echocardiography (MCE) formula estimates absolute myocardial blood flow (MBF) by normalizing myocardial contrast intensity to the left ventricular blood pool. Because Langendorff-perfused isolated hearts lack this physiological reference, we substituted the aortic-root blood pool to evaluate formula transferability and develop a condition-specific calibration. Twenty-four rabbit hearts underwent constant-flow perfusion at 21 mL/min and flash-replenishment MCE during continuous microbubble infusion. Plateau intensity (A), replenishment rate constant (β), and A × β were measured, with segment-matched fluorescent-microsphere-derived MBF as the reference. Of 408 segments, 407 were analyzed. The adapted estimate preserved the basal-to-apical perfusion pattern but showed poor agreement with reference MBF (CCC = 0.080; RMSE = 3.479 mL·min⁻¹·g⁻¹). After adjustment for myocardial level, the adapted estimate did not improve model fit ( P = 0.328), whereas A × β remained associated with reference MBF ( P = 0.005). The final mixed-effects calibration equation was MBF = 2.863 + 0.176I_Basal − 0.906I_Apical + 0.012(A × β). Adding A × β to myocardial level alone changed leave-one-heart-out cross-validation RMSE from 0.510 to 0.508 mL·min⁻¹·g⁻¹ and CCC from 0.648 to 0.653. Predictive performance was driven predominantly by myocardial level, with A × β providing modest additional predictive information. This condition-specific proof-of-concept calibration under standardized constant-flow conditions requires validation in independent preparations and across broader perfusion conditions before wider application.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-12
DOI
https://doi.org/10.1038/s41598-026-78471-9
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Transferability of the classic volumetric myocardial contrast echocardiography formula to constant-flow Langendorff-perfused rabbit hearts

Yuming Mu, peipei Mai, Xinchen Ren, Lina Guan et al.
Scientific Reports
Cardiac Imaging and Diagnostics
article

Transferability of the classic volumetric myocardial contrast echocardiography formula to constant-flow Langendorff-perfused rabbit hearts

Yuming Mu, peipei Mai, Xinchen Ren, Lina Guan, Lihong Wang, Jin Zhang
article en

Abstract

The classic volumetric myocardial contrast echocardiography (MCE) formula estimates absolute myocardial blood flow (MBF) by normalizing myocardial contrast intensity to the left ventricular blood pool. Because Langendorff-perfused isolated hearts lack this physiological reference, we substituted the aortic-root blood pool to evaluate formula transferability and develop a condition-specific calibration. Twenty-four rabbit hearts underwent constant-flow perfusion at 21 mL/min and flash-replenishment MCE during continuous microbubble infusion. Plateau intensity (A), replenishment rate constant (β), and A × β were measured, with segment-matched fluorescent-microsphere-derived MBF as the reference. Of 408 segments, 407 were analyzed. The adapted estimate preserved the basal-to-apical perfusion pattern but showed poor agreement with reference MBF (CCC = 0.080; RMSE = 3.479 mL·min⁻¹·g⁻¹). After adjustment for myocardial level, the adapted estimate did not improve model fit ( P = 0.328), whereas A × β remained associated with reference MBF ( P = 0.005). The final mixed-effects calibration equation was MBF = 2.863 + 0.176I_Basal − 0.906I_Apical + 0.012(A × β). Adding A × β to myocardial level alone changed leave-one-heart-out cross-validation RMSE from 0.510 to 0.508 mL·min⁻¹·g⁻¹ and CCC from 0.648 to 0.653. Predictive performance was driven predominantly by myocardial level, with A × β providing modest additional predictive information. This condition-specific proof-of-concept calibration under standardized constant-flow conditions requires validation in independent preparations and across broader perfusion conditions before wider application.

Scientific Reports
Chinese Academy of Sciences (CN), First Affiliated Hospital of Xinjiang Medical University (CN), Gannan Medical University (CN), Shenzhen Institutes of Advanced Technology (CN)
Xinjiang Medical University, Natural Science Foundation of Xinjiang
Good health and well-being
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon