A Computational Based Platform for the Design of [PtCl₆]²⁻ Anion Receptors

This poster was presented at the CHPC National Conference 2023 (Centre for High Performance Computing, South Africa). It describes an automated multilevel computational workflow for designing and evaluating anion receptors for the hexachloroplatinate(IV) anion, [PtCl₆]²⁻, in water. Background. Computational chemistry is still not reliable for designing anion receptors a priori when they have to work in highly polar solvents such as water. This matters for platinum group metal (PGM) refining. There, [PtCl₆]²⁻ has to be recovered selectively from strongly acidic, high-chloride process streams that also contain many competing metal chlorido complexes. Experimental receptor development usually runs as a slow loop of design, synthesis and evaluation by solvent extraction (SX) or column studies, and it often ends at a sub-optimal result. Methodology. Triethylenetetramine (trien) and its derivatives were used as a case study. Using the CREST and CENSO algorithms with the ORCA quantum chemistry package, the workflow screens conformer ensembles for systems of about 100–200 atoms in a funnel of stages: Constrained conformer sampling with DFT single-point energies Constrained, then unconstrained, DFT optimisations DLPNO-CCSD(T) single-point energies Final free energies The workflow combines r²SCAN-3c electronic energies, GFN2-xTB/ALPB/SPH thermostatistical contributions, and continuum solvation (ALPB, COSMO-RS). It computes conformational equilibria, pKₐ values, solvation free energies, and interaction enthalpies and entropies. Complexation is broken down as ΔG_f^calc = ΔG_b^gas + ΔG_def + ΣΔG^solv, which separates gas-phase binding, ligand preorganisation (deformation) and solvation. Calculations ran in parallel on the CHPC Lengau cluster (24 cores, 40 GB memory per job). Results. Computed stepwise protonation constants of the trien ligand match isothermal titration calorimetry (ITC) data closely: Step Computed pKₐ ITC pKₐ 1 10.19 10.37 2 10.06 10.00 3 7.65 7.70 4 4.15 4.49 The computed free energy for forming [(H₄L)PtCl₆]²⁺ is −14.7 kJ/mol, compared with −17.8 kJ/mol from experiment. Key finding. Many anion receptor design strategies emphasise preorganisation. For this system, however, the solvation free energy of the anion–ligand complex outweighs the free energy of ligand preorganisation. This points to solvation as a central design parameter for PGM-selective receptors in water. Acknowledgements. Computational resources were provided by the Centre for High Performance Computing (CHPC), part of the National Integrated Cyberinfrastructure System (NICIS), South Africa

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-12
DOI
https://doi.org/10.5281/zenodo.24164120
Primary Topic
Advanced Chemical Physics Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Computational Based Platform for the Design of [PtCl₆]²⁻ Anion Receptors

Matteo Savastano, Zenixole R. Tshentu, Antonio Bianchi, Cyprian Moyo
Zenodo (CERN European Organization for Nuclear Research)
Advanced Chemical Physics Studies
article

A Computational Based Platform for the Design of [PtCl₆]²⁻ Anion Receptors

Matteo Savastano, Zenixole R. Tshentu, Antonio Bianchi, Cyprian Moyo
article en

Abstract

This poster was presented at the CHPC National Conference 2023 (Centre for High Performance Computing, South Africa). It describes an automated multilevel computational workflow for designing and evaluating anion receptors for the hexachloroplatinate(IV) anion, [PtCl₆]²⁻, in water. Background. Computational chemistry is still not reliable for designing anion receptors a priori when they have to work in highly polar solvents such as water. This matters for platinum group metal (PGM) refining. There, [PtCl₆]²⁻ has to be recovered selectively from strongly acidic, high-chloride process streams that also contain many competing metal chlorido complexes. Experimental receptor development usually runs as a slow loop of design, synthesis and evaluation by solvent extraction (SX) or column studies, and it often ends at a sub-optimal result. Methodology. Triethylenetetramine (trien) and its derivatives were used as a case study. Using the CREST and CENSO algorithms with the ORCA quantum chemistry package, the workflow screens conformer ensembles for systems of about 100–200 atoms in a funnel of stages: Constrained conformer sampling with DFT single-point energies Constrained, then unconstrained, DFT optimisations DLPNO-CCSD(T) single-point energies Final free energies The workflow combines r²SCAN-3c electronic energies, GFN2-xTB/ALPB/SPH thermostatistical contributions, and continuum solvation (ALPB, COSMO-RS). It computes conformational equilibria, pKₐ values, solvation free energies, and interaction enthalpies and entropies. Complexation is broken down as ΔG_f^calc = ΔG_b^gas + ΔG_def + ΣΔG^solv, which separates gas-phase binding, ligand preorganisation (deformation) and solvation. Calculations ran in parallel on the CHPC Lengau cluster (24 cores, 40 GB memory per job). Results. Computed stepwise protonation constants of the trien ligand match isothermal titration calorimetry (ITC) data closely: Step Computed pKₐ ITC pKₐ 1 10.19 10.37 2 10.06 10.00 3 7.65 7.70 4 4.15 4.49 The computed free energy for forming [(H₄L)PtCl₆]²⁺ is −14.7 kJ/mol, compared with −17.8 kJ/mol from experiment. Key finding. Many anion receptor design strategies emphasise preorganisation. For this system, however, the solvation free energy of the anion–ligand complex outweighs the free energy of ligand preorganisation. This points to solvation as a central design parameter for PGM-selective receptors in water. Acknowledgements. Computational resources were provided by the Centre for High Performance Computing (CHPC), part of the National Integrated Cyberinfrastructure System (NICIS), South Africa

Zenodo (CERN European Organization for Nuclear Research)
San Raffaele University of Rome (IT), University of Florence (IT), Nelson Mandela University (ZA)
Advanced Chemical Physics Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon