Photon efficiency–coherence time product rule for NV-centre and trapped-ion quantum repeater chains

Abstract The fidelity of a first-generation quantum repeater is controlled by a single hardware quantity, whose identification explains a striking equivalence between the two leading qubit platforms. By simulating nitrogen-vacancy (NV) center and trapped-ion (171Yb+) repeater chains over an identical 200km fiber channel—anchored to optical time-domain reflectometry (OTDR) field measurements of a deployed single-mode link and statistically extended to 66.08 dB total loss - we find that the two platforms deliver statistically indistinguishable raw fidelity at three segments (NV: Ftel = 0.605; trapped ion: Ftel = 0.589), despite five-fold opposite photon-efficiency and coherence-time specifications. A two-dimensional sensitivity analysis reveals why: at fixed channel loss, repeater fidelity is controlled by the product νphoton·T2 of photon efficiency and coherence time, not by either quantity alone. Both platforms share νphoton·T2 = 0.20s and therefore perform identically; any two platforms on the same iso-product line will likewise coincide. This design rule yields a concrete hardware target: reaching the BB84 key-distribution threshold at three segments requires νphoton·T2 ≥ 2.44s, a twelve-fold improvement, and at the throughput-optimal segment count gate and measurement errors cap fidelity near 0.806 regardless of memory quality. The comparison is built on the NetSquid discrete-event simulator with experimentally validated parameters, full three-basis state tomography, and density-matrix DEJMPS purification; the last reveals that realistic dephasing-biased chain states purify substantially better than the Werner-state recurrence predicts. Trapped ions purify more effectively (Bell fidelity 0.608 versus 0.509 after one round) owing to superior gate and read out fidelity, while NV centers generate entangled pairs 4–5×faster. The photon–memory interface, captured by the νphoton·T2 product, is the universal bottleneck limiting both platforms.

Authors

Institutions

Publication Details

Journal
Physica Scripta
Published
2026-11-12
DOI
https://doi.org/10.1088/1402-4896/aec11b
Primary Topic
Quantum Information and Cryptography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Photon efficiency–coherence time product rule for NV-centre and trapped-ion quantum repeater chains

Nanda Bikram Adhikari, Samir Thapa
Physica Scripta
Quantum Information and Cryptography
article

Photon efficiency–coherence time product rule for NV-centre and trapped-ion quantum repeater chains

Nanda Bikram Adhikari, Samir Thapa
article en

Abstract

Abstract The fidelity of a first-generation quantum repeater is controlled by a single hardware quantity, whose identification explains a striking equivalence between the two leading qubit platforms. By simulating nitrogen-vacancy (NV) center and trapped-ion (171Yb+) repeater chains over an identical 200km fiber channel—anchored to optical time-domain reflectometry (OTDR) field measurements of a deployed single-mode link and statistically extended to 66.08 dB total loss - we find that the two platforms deliver statistically indistinguishable raw fidelity at three segments (NV: Ftel = 0.605; trapped ion: Ftel = 0.589), despite five-fold opposite photon-efficiency and coherence-time specifications. A two-dimensional sensitivity analysis reveals why: at fixed channel loss, repeater fidelity is controlled by the product νphoton·T2 of photon efficiency and coherence time, not by either quantity alone. Both platforms share νphoton·T2 = 0.20s and therefore perform identically; any two platforms on the same iso-product line will likewise coincide. This design rule yields a concrete hardware target: reaching the BB84 key-distribution threshold at three segments requires νphoton·T2 ≥ 2.44s, a twelve-fold improvement, and at the throughput-optimal segment count gate and measurement errors cap fidelity near 0.806 regardless of memory quality. The comparison is built on the NetSquid discrete-event simulator with experimentally validated parameters, full three-basis state tomography, and density-matrix DEJMPS purification; the last reveals that realistic dephasing-biased chain states purify substantially better than the Werner-state recurrence predicts. Trapped ions purify more effectively (Bell fidelity 0.608 versus 0.509 after one round) owing to superior gate and read out fidelity, while NV centers generate entangled pairs 4–5×faster. The photon–memory interface, captured by the νphoton·T2 product, is the universal bottleneck limiting both platforms.

Physica Scripta
Pulchowk Campus (NP)
Quantum Information and Cryptography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon