A Multi-Cohort nnU-Net for White Matter Hyperintensity Segmentation Across 2D and 3D FLAIR Acquisitions

Background White matter hyperintensities (WMH) are increasingly pooled across aging, cerebral small vessel disease (CSVD), and dementia cohorts that differ in both disease composition and FLAIR acquisition. Most automated segmentation tools were developed within a narrower range of populations or protocols, and few have been tested for whether segmentation accuracy and error remain consistent across conventional 2D and isotropic 3D FLAIR, or whether the choice of algorithm alters downstream clinical associations. Methods We developed a single nnU-Net model, taking FLAIR and T1-weighted images as inputs, using 460 2D and 3D FLAIR scans from a neurodegenerative cohort (Alzheimer's Disease Neuroimaging Initiative, ADNI), a CSVD-enriched cohort with same-visit paired 2D and 3D FLAIR (Washington University White Matter Ischemic-Hypoxia study, WWISH), and a population-based sample (UK Biobank), holding out 92 scans from 66 participants at the participant-level as an internal test set. We further evaluated the model in an independent ADNI3 3D FLAIR set (n = 25), benchmarking voxel-wise overlap (Dice), volumetric agreement, and lesion-level detection against SHIVA-WMH, segcsvdWMH, and FreeSurfer WMH-SynthSeg, and compared acquisition-specific volume bias in participants with paired 2D and 3D FLAIR. We then compared how WMH volumes from each method predicted incident dementia in cognitively unimpaired adults from ADNI and the Knight Alzheimer Disease Research Center (n = 1,174; 42 incident cases). Results In the internal test set, the model achieved a mean Dice of 0.73 (SD 0.10), compared with 0.50, 0.57, and 0.29 for SHIVA-WMH, segcsvdWMH, and WMH-SynthSeg (all FDR-adjusted p < 0.001). Dice was similar on 2D and 3D FLAIR (0.75 vs. 0.71). In WWISH participants imaged with both acquisitions, mean volume bias differed between 2D and 3D scans by 1.8 mL for the model versus 4.7-9.9 mL for the comparators. Advantages were largest in low-burden scans (<5 mL; Dice 0.66 vs. 0.19-0.54) and for lesions of ≤100 voxels (detection 77-87% vs. 14-63%). In ADNI3, the model retained a mean Dice of 0.70 (SD 0.14) without retraining and exceeded all comparators (FDR-adjusted p ≤ 0.002). Model-derived WMH volume was associated with incident dementia beyond clinical covariates (OR per SD 1.40, 95% CI 1.11-1.77; likelihood-ratio p = 0.009; cross-validated AUC 0.71 vs. 0.68), whereas comparator-derived volumes did not significantly improve model fit. Conclusions Training a single model across disease contexts and FLAIR acquisitions yielded WMH segmentation that was similarly accurate on 2D and 3D FLAIR, sensitive to low-burden disease, transferable to an unseen protocol, and clinically informative, supporting its use in multi-cohort, mixed-etiology studies.

Authors

Institutions

Publication Details

Journal
medRxiv
Published
2026-11-12
DOI
https://doi.org/10.64898/2026.11.11.26367656
Primary Topic
Medical Image Segmentation Techniques
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

A Multi-Cohort nnU-Net for White Matter Hyperintensity Segmentation Across 2D and 3D FLAIR Acquisitions

Serguei V. Astafiev, Yasheng Chen, Uttam Khatri, jin-moo lee et al.
medRxiv
Medical Image Segmentation Techniques
preprint

A Multi-Cohort nnU-Net for White Matter Hyperintensity Segmentation Across 2D and 3D FLAIR Acquisitions

Serguei V. Astafiev, Yasheng Chen, Uttam Khatri, jin-moo lee, Chia‐Ling Phuah, Byron Xu, Hongyu An, Andria Ford
preprint en

Abstract

Background White matter hyperintensities (WMH) are increasingly pooled across aging, cerebral small vessel disease (CSVD), and dementia cohorts that differ in both disease composition and FLAIR acquisition. Most automated segmentation tools were developed within a narrower range of populations or protocols, and few have been tested for whether segmentation accuracy and error remain consistent across conventional 2D and isotropic 3D FLAIR, or whether the choice of algorithm alters downstream clinical associations. Methods We developed a single nnU-Net model, taking FLAIR and T1-weighted images as inputs, using 460 2D and 3D FLAIR scans from a neurodegenerative cohort (Alzheimer's Disease Neuroimaging Initiative, ADNI), a CSVD-enriched cohort with same-visit paired 2D and 3D FLAIR (Washington University White Matter Ischemic-Hypoxia study, WWISH), and a population-based sample (UK Biobank), holding out 92 scans from 66 participants at the participant-level as an internal test set. We further evaluated the model in an independent ADNI3 3D FLAIR set (n = 25), benchmarking voxel-wise overlap (Dice), volumetric agreement, and lesion-level detection against SHIVA-WMH, segcsvdWMH, and FreeSurfer WMH-SynthSeg, and compared acquisition-specific volume bias in participants with paired 2D and 3D FLAIR. We then compared how WMH volumes from each method predicted incident dementia in cognitively unimpaired adults from ADNI and the Knight Alzheimer Disease Research Center (n = 1,174; 42 incident cases). Results In the internal test set, the model achieved a mean Dice of 0.73 (SD 0.10), compared with 0.50, 0.57, and 0.29 for SHIVA-WMH, segcsvdWMH, and WMH-SynthSeg (all FDR-adjusted p < 0.001). Dice was similar on 2D and 3D FLAIR (0.75 vs. 0.71). In WWISH participants imaged with both acquisitions, mean volume bias differed between 2D and 3D scans by 1.8 mL for the model versus 4.7-9.9 mL for the comparators. Advantages were largest in low-burden scans (<5 mL; Dice 0.66 vs. 0.19-0.54) and for lesions of ≤100 voxels (detection 77-87% vs. 14-63%). In ADNI3, the model retained a mean Dice of 0.70 (SD 0.14) without retraining and exceeded all comparators (FDR-adjusted p ≤ 0.002). Model-derived WMH volume was associated with incident dementia beyond clinical covariates (OR per SD 1.40, 95% CI 1.11-1.77; likelihood-ratio p = 0.009; cross-validated AUC 0.71 vs. 0.68), whereas comparator-derived volumes did not significantly improve model fit. Conclusions Training a single model across disease contexts and FLAIR acquisitions yielded WMH segmentation that was similarly accurate on 2D and 3D FLAIR, sensitive to low-burden disease, transferable to an unseen protocol, and clinically informative, supporting its use in multi-cohort, mixed-etiology studies.

medRxiv
Barrow Neurological Institute (US), Washington University in St. Louis (US), Mallinckrodt (United States) (US)
Good health and well-being
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon