Design Blueprint: An Adiabatic Compressed-Air Store in a Salt Cavern: Air Mass, Cavern Volume, Compression Heat Recovery and Round-Trip Budget for Twenty Thousand Usable Kilowatt-Hours

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24173781): This paper sizes a adiabatic compressed-air storage system for a wind farm requiring overnight shifting of surplus generation. The duty calls for 2e+04 usable electrical kilowatt-hours delivered at a rated power of 3e+03 kilowatts. Working from a stated specific energy of 8 watt-hours per kilogram, an energy density of 4 watt-hours per litre, a usable depth-of-discharge fraction of 0.95, and a round-trip efficiency of 65 percent, the calculation gives a gross stored energy of 2.11e+04 kilowatt-hours, an active-store mass of 2.63e+06 kilograms, a complete system mass of 2.89e+06 kilograms, and a complete system volume of 5.79e+06 litres (5.79e+03 cubic metres). Full discharge at rated power lasts 6.67 hours, and a full recharge takes 10.4 hours at the stated charge power. Losses amount to 9.14e+03 kilowatt-hours per complete cycle, appearing as heat at average rates of 438 kilowatts during charging and 685 kilowatts during discharge. Standing loss is 0.01 percent of the stored energy per day. Life is limited by the cycle limit, giving 1e+04 effective full cycles, about 40 years at the assumed cycling rate, and a lifetime delivered throughput of 2e+05 megawatt-hours. All values are computed from the stated assumptions; the system is a design study and has not been built or measured. Status: SIMULATED, NOT MEASURED. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-12
DOI
https://doi.org/10.5281/zenodo.24175291
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Design Blueprint: An Adiabatic Compressed-Air Store in a Salt Cavern: Air Mass, Cavern Volume, Compression Heat Recovery and Round-Trip Budget for Twenty Thousand Usable Kilowatt-Hours

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
preprint

Design Blueprint: An Adiabatic Compressed-Air Store in a Salt Cavern: Air Mass, Cavern Volume, Compression Heat Recovery and Round-Trip Budget for Twenty Thousand Usable Kilowatt-Hours

William Alexander Aldred
preprint en

Abstract

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24173781): This paper sizes a adiabatic compressed-air storage system for a wind farm requiring overnight shifting of surplus generation. The duty calls for 2e+04 usable electrical kilowatt-hours delivered at a rated power of 3e+03 kilowatts. Working from a stated specific energy of 8 watt-hours per kilogram, an energy density of 4 watt-hours per litre, a usable depth-of-discharge fraction of 0.95, and a round-trip efficiency of 65 percent, the calculation gives a gross stored energy of 2.11e+04 kilowatt-hours, an active-store mass of 2.63e+06 kilograms, a complete system mass of 2.89e+06 kilograms, and a complete system volume of 5.79e+06 litres (5.79e+03 cubic metres). Full discharge at rated power lasts 6.67 hours, and a full recharge takes 10.4 hours at the stated charge power. Losses amount to 9.14e+03 kilowatt-hours per complete cycle, appearing as heat at average rates of 438 kilowatts during charging and 685 kilowatts during discharge. Standing loss is 0.01 percent of the stored energy per day. Life is limited by the cycle limit, giving 1e+04 effective full cycles, about 40 years at the assumed cycling rate, and a lifetime delivered throughput of 2e+05 megawatt-hours. All values are computed from the stated assumptions; the system is a design study and has not been built or measured. Status: SIMULATED, NOT MEASURED. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Zenodo (CERN European Organization for Nuclear Research)
Climate action, Affordable and clean energy, Industry, innovation and infrastructure
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.