Design Blueprint: A Vanadium Redox Flow Store for a Rural Clinic: Tank Volume, Stack Power, Pumping Loss and Decoupled Energy Scaling for Forty Usable Kilowatt-Hours

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24174193): This paper sizes a vanadium redox flow storage system for a rural clinic requiring overnight refrigeration, lighting and instrument supply. The duty calls for 40 usable electrical kilowatt-hours delivered at a rated power of 8 kilowatts. Working from a stated specific energy of 22 watt-hours per kilogram, an energy density of 25 watt-hours per litre, a usable depth-of-discharge fraction of 0.8, and a round-trip efficiency of 75 percent, the calculation gives a gross stored energy of 50 kilowatt-hours, an active-store mass of 2.27e+03 kilograms, a complete system mass of 3.64e+03 kilograms, and a complete system volume of 3.2e+03 litres (3.2 cubic metres). Full discharge at rated power lasts 5 hours, and a full recharge takes 7.22 hours at the stated charge power. Losses amount to 14.4 kilowatt-hours per complete cycle, appearing as heat at average rates of 1 kilowatts during charging and 1.44 kilowatts during discharge. Standing loss is 0.1 percent of the stored energy per day. Life is limited by the calendar limit, giving 6e+03 effective full cycles, about 20 years at the assumed cycling rate, and a lifetime delivered throughput of 240 megawatt-hours. All values are computed from the stated assumptions; the system is a design study and has not been built or measured. Status: SIMULATED, NOT MEASURED. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-12
DOI
https://doi.org/10.5281/zenodo.24175523
Primary Topic
Aqueous and Flow Batteries
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Design Blueprint: A Vanadium Redox Flow Store for a Rural Clinic: Tank Volume, Stack Power, Pumping Loss and Decoupled Energy Scaling for Forty Usable Kilowatt-Hours

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Aqueous and Flow Batteries
preprint

Design Blueprint: A Vanadium Redox Flow Store for a Rural Clinic: Tank Volume, Stack Power, Pumping Loss and Decoupled Energy Scaling for Forty Usable Kilowatt-Hours

William Alexander Aldred
preprint en

Abstract

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24174193): This paper sizes a vanadium redox flow storage system for a rural clinic requiring overnight refrigeration, lighting and instrument supply. The duty calls for 40 usable electrical kilowatt-hours delivered at a rated power of 8 kilowatts. Working from a stated specific energy of 22 watt-hours per kilogram, an energy density of 25 watt-hours per litre, a usable depth-of-discharge fraction of 0.8, and a round-trip efficiency of 75 percent, the calculation gives a gross stored energy of 50 kilowatt-hours, an active-store mass of 2.27e+03 kilograms, a complete system mass of 3.64e+03 kilograms, and a complete system volume of 3.2e+03 litres (3.2 cubic metres). Full discharge at rated power lasts 5 hours, and a full recharge takes 7.22 hours at the stated charge power. Losses amount to 14.4 kilowatt-hours per complete cycle, appearing as heat at average rates of 1 kilowatts during charging and 1.44 kilowatts during discharge. Standing loss is 0.1 percent of the stored energy per day. Life is limited by the calendar limit, giving 6e+03 effective full cycles, about 20 years at the assumed cycling rate, and a lifetime delivered throughput of 240 megawatt-hours. All values are computed from the stated assumptions; the system is a design study and has not been built or measured. Status: SIMULATED, NOT MEASURED. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy, Industry, innovation and infrastructure, Responsible consumption and production, Climate action
Aqueous and Flow Batteries
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon