Limits on Hong-Ou-Mandel Visibility from Spectral and Temporal Mismatch Between Two Photons

Two photons arriving at a beam splitter interfere only to the extent that they are indistinguishable in every degree of freedom. Spectral detuning and arrival-time offset are the two mismatches most often left in a laboratory adjustment, and each one reduces the depth of the Hong-Ou-Mandel dip in a calculable way. This study computes the quantities that follow from stated assumptions for two heralded photons with Gaussian spectra of 1 GHz full width, a 50:50 beam splitter, and variable centre-frequency detuning and arrival delay, using the relations set out in the Methods. The headline results are visibility at half GHz detuning = 0.8, visibility at 1 GHz detuning = 0.5, visibility at 0.22 ns delay = 0.7788, combined visibility half GHz and 0.22 ns = 0.623, detuning for 90pct GHz = 0.3333. The central question is stated as follows: How much visibility remains for stated detunings and timing offsets between two Gaussian photons of 1 GHz bandwidth, and which mismatch reaches a ten percent visibility loss first? The answer obtained here is conditional on the assumptions listed in the paper and in the deposited calculation; changing an assumption changes the numbers in the way the sensitivity discussion describes. Interference visibilities above ninety percent are reported for well matched sources, while visibilities near fifty percent indicate a partly distinguishable pair, which gives a practical scale for the numbers computed here. The work is a computation, not a laboratory measurement, and it is labelled accordingly. Where the computed result is unfavourable to the device or effect under study, that outcome is reported in the same terms as a favourable one, because a bound that only appears when it is welcome is not a bound at all. All numerical statements in this abstract are reproduced by the deposited script from the stated inputs.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-12
DOI
https://doi.org/10.5281/zenodo.24159604
Primary Topic
Quantum Information and Cryptography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Limits on Hong-Ou-Mandel Visibility from Spectral and Temporal Mismatch Between Two Photons

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Quantum Information and Cryptography
article

Limits on Hong-Ou-Mandel Visibility from Spectral and Temporal Mismatch Between Two Photons

William Alexander Aldred
article en

Abstract

Two photons arriving at a beam splitter interfere only to the extent that they are indistinguishable in every degree of freedom. Spectral detuning and arrival-time offset are the two mismatches most often left in a laboratory adjustment, and each one reduces the depth of the Hong-Ou-Mandel dip in a calculable way. This study computes the quantities that follow from stated assumptions for two heralded photons with Gaussian spectra of 1 GHz full width, a 50:50 beam splitter, and variable centre-frequency detuning and arrival delay, using the relations set out in the Methods. The headline results are visibility at half GHz detuning = 0.8, visibility at 1 GHz detuning = 0.5, visibility at 0.22 ns delay = 0.7788, combined visibility half GHz and 0.22 ns = 0.623, detuning for 90pct GHz = 0.3333. The central question is stated as follows: How much visibility remains for stated detunings and timing offsets between two Gaussian photons of 1 GHz bandwidth, and which mismatch reaches a ten percent visibility loss first? The answer obtained here is conditional on the assumptions listed in the paper and in the deposited calculation; changing an assumption changes the numbers in the way the sensitivity discussion describes. Interference visibilities above ninety percent are reported for well matched sources, while visibilities near fifty percent indicate a partly distinguishable pair, which gives a practical scale for the numbers computed here. The work is a computation, not a laboratory measurement, and it is labelled accordingly. Where the computed result is unfavourable to the device or effect under study, that outcome is reported in the same terms as a favourable one, because a bound that only appears when it is welcome is not a bound at all. All numerical statements in this abstract are reproduced by the deposited script from the stated inputs.

Zenodo (CERN European Organization for Nuclear Research)
Quantum Information and Cryptography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon