The Integrated Sachs-Wolfe Signal of Stacked Supervoids: An Amplitude Test Against the Bounce Expansion History

Photons crossing an evolving void lose energy, and the stacked microwave temperature over supervoids is one of the few direct measurements of that loss. This paper computes the linear integrated Sachs-Wolfe signal for three representative structures, a Granett-type supervoid, a typical catalogue void, and an Eridanus-scale supervoid, in both the standard expansion history and a bounced history whose late-time behaviour differs by a stated three per cent in the potential-decay factor. The Granett-type structure gives -6.5 microkelvin in the standard calculation and -6.3 microkelvin with the bounce factor, the typical void gives -0.8 microkelvin, and the Eridanus-scale structure gives -14.5 microkelvin. The ratio of the historically reported stacked amplitude to the linear prediction is 1.69, quantifying the long-standing excess that neither history explains. A stack of fifty supervoids at the computed amplitude reaches a formal signal-to-noise of 0.9 against primary microwave noise alone. The conclusion is plain: the bounce changes the predicted signal by less than the current excess, so stacked void temperatures cannot currently separate the histories, and the excess remains a problem for both. All values are computed from stated assumptions, not measured.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-12
DOI
https://doi.org/10.5281/zenodo.24149981
Primary Topic
Cosmology and Gravitation Theories
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The Integrated Sachs-Wolfe Signal of Stacked Supervoids: An Amplitude Test Against the Bounce Expansion History

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Cosmology and Gravitation Theories
article

The Integrated Sachs-Wolfe Signal of Stacked Supervoids: An Amplitude Test Against the Bounce Expansion History

William Alexander Aldred
article en

Abstract

Photons crossing an evolving void lose energy, and the stacked microwave temperature over supervoids is one of the few direct measurements of that loss. This paper computes the linear integrated Sachs-Wolfe signal for three representative structures, a Granett-type supervoid, a typical catalogue void, and an Eridanus-scale supervoid, in both the standard expansion history and a bounced history whose late-time behaviour differs by a stated three per cent in the potential-decay factor. The Granett-type structure gives -6.5 microkelvin in the standard calculation and -6.3 microkelvin with the bounce factor, the typical void gives -0.8 microkelvin, and the Eridanus-scale structure gives -14.5 microkelvin. The ratio of the historically reported stacked amplitude to the linear prediction is 1.69, quantifying the long-standing excess that neither history explains. A stack of fifty supervoids at the computed amplitude reaches a formal signal-to-noise of 0.9 against primary microwave noise alone. The conclusion is plain: the bounce changes the predicted signal by less than the current excess, so stacked void temperatures cannot currently separate the histories, and the excess remains a problem for both. All values are computed from stated assumptions, not measured.

Zenodo (CERN European Organization for Nuclear Research)
Cosmology and Gravitation Theories
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon