Optimization of Trapezoidal Bottom Sills for Flow Pattern Control in Integrated Diversion Gate–pumping Station Hubs
This study investigates the system-level flow-control effect of trapezoidal bottom sills in an integrated diversion gate–pumping station hub. The relative sill height (h/H, where h is the sill height and H is the design water depth), relative streamwise placement (d/D, where d is the sill placement distance and D is the diffuser-section length), and sill width ratio (b/h, where b is the sill width) were selected as the design variables. A three-factor, five-level full-factorial computational-fluid-dynamics (CFD) experimental design was combined with entropy-weighted multi-indicator evaluation, recirculation-volume-ratio constraints, response surface methodology (RSM), engineering rounding, and CFD verification. The evaluation framework jointly considered velocity uniformity, flow-direction consistency, recirculation, and vortex intensity along the diversion basin–forebay–pump sump flow path. An entropy-weighted optimal parameter combination was first identified within the investigated design space and then rounded to an implementable engineering design with h/H = 0.35, d/D = 0.86, and b/h = 0.35. For this selected rounded design, the relative deviation between the RSM-predicted comprehensive objective value and the corresponding CFD-based value was 6.86%. Compared with the original scheme, the selected design increased forebay velocity uniformity by 28.22%, reduced the forebay recirculation area ratio by 90.25%, and improved the velocity-weighted mean flow angles at the forebay and pump sump inlet sections by 4.85% and 20.46%, respectively. The comprehensive vorticity indicators at the two evaluated sections decreased by 20.11% and 48.91%. The recirculation-volume ratios in the diversion basin and the C-direction gate approach channel–forebay–pump sump system decreased by 50% and 4.87%, respectively. Although the local hydraulic loss coefficient of the diversion basin increased from 7.948 to 21.790, the hydraulic efficiency of the pumping-station section changed only slightly from 96.4% to 96.3%, indicating that the selected design did not cause a substantial pumping-station efficiency penalty. Local RSM-based screening further identified the recirculation volume ratio in the C-direction gate approach channel–forebay–pump sump system as the governing feasibility constraint and showed that increasing d/D narrows the feasible neighborhood. The proposed framework provides a quantitative basis for selecting implementable trapezoidal bottom-sill geometries for hydraulic rectification in similar integrated diversion gate–pumping station hubs.
Authors
- H. Qin
- X. Yu
- Y. Wang
- J. Chen
- F. Xu
Institutions
- Hohai University (CN)
Publication Details
- Journal
- Journal of Applied Fluid Mechanics
- Published
- 2026-11-12
- DOI
- https://doi.org/10.47176/jafm.20.1.4699
- Primary Topic
- Hydraulic flow and structures
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Natural Science Foundation of China