CRISPR/Cas12a-Triggered Dual-Mode Electrochemical and Raman-Silent Surface-Enhanced Raman Scattering Biosensing for Sensitive HBV DNA Detection

Abstract Sensitive and reliable quantification of hepatitis B virus (HBV) DNA is important for monitoring viral replication and therapeutic response. Electrochemical (EC) sensing offers simple quantitative readout, but resolving current changes at low target concentrations remains challenging. Surface-enhanced Raman scattering (SERS), in contrast, provides signal amplification but generally requires specialized optical instrumentation and may suffer from matrix interference. To accommodate different analytical requirements, we developed a CRISPR/Cas12a-triggered dual-mode EC/SERS biosensing platform. This platform integrates a conductive/plasmonic gold nanoparticles (Au NPs)/copper(II)-2,3,6,7,10,11-hexahydroxytriphenylene (Cu3(HHTP)2)/indium tin oxide (ITO) interface with a CRISPR-responsive DNA hydrogel. The hydrogel serves as a target-responsive interfacial gate, with Cas12a-mediated cleavage regulating electrode accessibility to facilitate EC transduction and promote plasmonic coupling between SERS tags and Au NPs. Ag@Au nanocubes functionalized with 4-mercaptobenzonitrile were employed as SERS tags, providing a characteristic CN signal at 2228 cm−1 in the Raman-silent region. The EC mode exhibited a linear response to the logarithm of HBV DNA concentration from 100 fM to 10 nM, with a limit of detection (LOD) of 17.1 fM. The SERS mode was evaluated in parallel on a separate, identically prepared hydrogel-modified electrode, yielding a linear range of 5 fM to 1 nM and an LOD of 0.143 fM. This platform combines the operational simplicity and quantitative capability of EC sensing with the high sensitivity of SERS detection, providing complementary readout options for different HBV DNA testing requirements.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-11-12
DOI
https://doi.org/10.1021/acs.analchem.6c06805
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

CRISPR/Cas12a-Triggered Dual-Mode Electrochemical and Raman-Silent Surface-Enhanced Raman Scattering Biosensing for Sensitive HBV DNA Detection

Fang Luo, Zhenyu Lin, Xiaoyi Chen, Zhenjie Zheng et al.
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
article

CRISPR/Cas12a-Triggered Dual-Mode Electrochemical and Raman-Silent Surface-Enhanced Raman Scattering Biosensing for Sensitive HBV DNA Detection

Fang Luo, Zhenyu Lin, Xiaoyi Chen, Zhenjie Zheng, Mengqi Ma, Xinyu Zhou, Xianghui Li, Tony Ye Hu
article en

Abstract

Abstract Sensitive and reliable quantification of hepatitis B virus (HBV) DNA is important for monitoring viral replication and therapeutic response. Electrochemical (EC) sensing offers simple quantitative readout, but resolving current changes at low target concentrations remains challenging. Surface-enhanced Raman scattering (SERS), in contrast, provides signal amplification but generally requires specialized optical instrumentation and may suffer from matrix interference. To accommodate different analytical requirements, we developed a CRISPR/Cas12a-triggered dual-mode EC/SERS biosensing platform. This platform integrates a conductive/plasmonic gold nanoparticles (Au NPs)/copper(II)-2,3,6,7,10,11-hexahydroxytriphenylene (Cu3(HHTP)2)/indium tin oxide (ITO) interface with a CRISPR-responsive DNA hydrogel. The hydrogel serves as a target-responsive interfacial gate, with Cas12a-mediated cleavage regulating electrode accessibility to facilitate EC transduction and promote plasmonic coupling between SERS tags and Au NPs. Ag@Au nanocubes functionalized with 4-mercaptobenzonitrile were employed as SERS tags, providing a characteristic CN signal at 2228 cm−1 in the Raman-silent region. The EC mode exhibited a linear response to the logarithm of HBV DNA concentration from 100 fM to 10 nM, with a limit of detection (LOD) of 17.1 fM. The SERS mode was evaluated in parallel on a separate, identically prepared hydrogel-modified electrode, yielding a linear range of 5 fM to 1 nM and an LOD of 0.143 fM. This platform combines the operational simplicity and quantitative capability of EC sensing with the high sensitivity of SERS detection, providing complementary readout options for different HBV DNA testing requirements.

Analytical Chemistry
Fujian Medical University (CN), Xiamen University (CN), Fuzhou University (CN), Tsinghua University (CN)
National Natural Science Foundation of China, Fuzhou University
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon