Comparative Assessment of Pre-Dialysis Fluid Status Using Clinical, Lung, and IVC Ultrasound Methods with Bioimpedance Spectroscopy as Reference Standard in Hemodialysis Patients

Background: Accurate assessment of overhydration in maintenance hemodialysis (MHD) patients remains challenging. The clinical method is widely used but may be unreliable. This study compared the nephrologist’s clinical method, lung ultrasound (LUS), and inferior vena cava (IVC) ultrasound against bioimpedance spectroscopy using a body composition monitor (BCM). Methods: In this single-center cross-sectional study, 98 hypertensive patients receiving twice-weekly MHD were evaluated within 30 min before the second dialysis session of the week. LUS B-lines, IVC diameter index at expiration (IVCDimax), and IVC collapsibility index (IVCCi) were measured. BCM-defined overhydration (>2.5 L) was the reference standard. Results: BCM classified 88/98 (89.8%) patients as overhydrated; among these, LUS, IVC ultrasound, and nephrologist’s clinical classification identified 86, 82, and 65 patients, respectively. LUS B-lines showed the strongest correlation with BCM-defined overhydration (ρ = 0.913) and the highest observed AUC (0.985; exploratory cutoff ≥12 B-lines: sensitivity 97.7%, specificity 90.0%). IVCCi showed a strong inverse correlation (r = −0.830; AUC = 0.940), while IVCDimax showed a moderate correlation (ρ = 0.641; AUC = 0.853). Clinically estimated overhydration showed a strong correlation (r = 0.797) but lower discriminative ability (AUC = 0.679) and a mean bias of −0.887 L. Conclusions: LUS had the highest observed AUC; nephrologist’s clinical classification missed more BCM-defined overhydrated patients than LUS or IVC ultrasound.

Authors

Institutions

Publication Details

Journal
Kidney and Dialysis
Published
2026-11-12
DOI
https://doi.org/10.3390/kidneydial6040071
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparative Assessment of Pre-Dialysis Fluid Status Using Clinical, Lung, and IVC Ultrasound Methods with Bioimpedance Spectroscopy as Reference Standard in Hemodialysis Patients

Ajith M. Nayak, Bharathi Dharmanna Naik, Dharshan Rangaswamy, Mohan Varadanayakanahalli Bhojaraja et al.
Kidney and Dialysis
Ultrasound in Clinical Applications
article

Comparative Assessment of Pre-Dialysis Fluid Status Using Clinical, Lung, and IVC Ultrasound Methods with Bioimpedance Spectroscopy as Reference Standard in Hemodialysis Patients

Ajith M. Nayak, Bharathi Dharmanna Naik, Dharshan Rangaswamy, Mohan Varadanayakanahalli Bhojaraja, Shwetha Prabhu, Indu Ramachandra Rao, Shankar Prasad Nagaraju, Attur Ravindra Prabhu, Srinivas Vinayak Shenoy
article en

Abstract

Background: Accurate assessment of overhydration in maintenance hemodialysis (MHD) patients remains challenging. The clinical method is widely used but may be unreliable. This study compared the nephrologist’s clinical method, lung ultrasound (LUS), and inferior vena cava (IVC) ultrasound against bioimpedance spectroscopy using a body composition monitor (BCM). Methods: In this single-center cross-sectional study, 98 hypertensive patients receiving twice-weekly MHD were evaluated within 30 min before the second dialysis session of the week. LUS B-lines, IVC diameter index at expiration (IVCDimax), and IVC collapsibility index (IVCCi) were measured. BCM-defined overhydration (>2.5 L) was the reference standard. Results: BCM classified 88/98 (89.8%) patients as overhydrated; among these, LUS, IVC ultrasound, and nephrologist’s clinical classification identified 86, 82, and 65 patients, respectively. LUS B-lines showed the strongest correlation with BCM-defined overhydration (ρ = 0.913) and the highest observed AUC (0.985; exploratory cutoff ≥12 B-lines: sensitivity 97.7%, specificity 90.0%). IVCCi showed a strong inverse correlation (r = −0.830; AUC = 0.940), while IVCDimax showed a moderate correlation (ρ = 0.641; AUC = 0.853). Clinically estimated overhydration showed a strong correlation (r = 0.797) but lower discriminative ability (AUC = 0.679) and a mean bias of −0.887 L. Conclusions: LUS had the highest observed AUC; nephrologist’s clinical classification missed more BCM-defined overhydrated patients than LUS or IVC ultrasound.

Kidney and DialysisVol. 6(4)
Manipal Academy of Higher Education (IN), Indian Institute of Technology Delhi (IN), Kasturba Medical College, Manipal (IN)
Indian Council of Medical Research
Good health and well-being
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon