MALDI-MS for Fast Analysis of PFOS Partitioning in Bacterial Biomass

Per- and polyfluoroalkyl substances (PFAS) are persistent environmental contaminants whose interactions with biological matrices are increasingly important to characterize. Conventional PFAS analysis in biological matrices using liquid chromatography-mass spectrometry (LC-MS) methods typically require extensive sample extraction and cleanup, limiting the throughput of PFAS screening. In this work, we developed a matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) workflow for direct detection and quantification of perfluorooctanesulfonic acid (PFOS) in bacterial biomass following exposure. Bacteria are ubiquitous in natural and engineered environments and may contribute to PFAS fate and transport. The diversity of PFAS structures and bacterial species leads to many exposure scenarios, making it an ideal system to develop fast screening methods for PFAS partitioning. Calibration curves of different ranges were first evaluated in both water and Escherichia coli ( E. coli ) biomass matrix-matched samples. Stable isotope-labeled internal standard, 13 C 8 -PFOS, was used for both calibration curves and samples to enable quantification. E. coli suspensions were exposed to PFOS, and the resulting biomass was washed, added with internal standard, lysed, and directly deposited onto a MALDI target with 1,5-diaminonaphthalene as the MALDI matrix for analysis. Comparable, low-ppb (µg/L) limit of quantification was determined for calibration curves in water and biomass sample matrices. Using external calibration curves and isotopically labeled standards, we quantified the amount of PFOS associated with bacterial biomass and found that the partitioning is time- and dose-dependent. The workflow allowed direct detection of PFOS from processed bacterial biomass with significantly reduced sample preparation and instrumental analysis time, establishing MALDI-MS as a rapid and quantitative approach for PFAS analysis and providing a foundation for higher-throughput screening of PFAS across diverse biological samples.

Authors

Institutions

Publication Details

Journal
ChemRxiv
Published
2026-11-12
DOI
https://doi.org/10.26434/chemrxiv.15012018/v1
Primary Topic
Per- and polyfluoroalkyl substances research
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

MALDI-MS for Fast Analysis of PFOS Partitioning in Bacterial Biomass

Helen O'Shaughnessy, Tian Autumn Qiu, Irfath Jasmin Reza
ChemRxiv
Per- and polyfluoroalkyl substances research
preprint

MALDI-MS for Fast Analysis of PFOS Partitioning in Bacterial Biomass

Helen O'Shaughnessy, Tian Autumn Qiu, Irfath Jasmin Reza
preprint en

Abstract

Per- and polyfluoroalkyl substances (PFAS) are persistent environmental contaminants whose interactions with biological matrices are increasingly important to characterize. Conventional PFAS analysis in biological matrices using liquid chromatography-mass spectrometry (LC-MS) methods typically require extensive sample extraction and cleanup, limiting the throughput of PFAS screening. In this work, we developed a matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) workflow for direct detection and quantification of perfluorooctanesulfonic acid (PFOS) in bacterial biomass following exposure. Bacteria are ubiquitous in natural and engineered environments and may contribute to PFAS fate and transport. The diversity of PFAS structures and bacterial species leads to many exposure scenarios, making it an ideal system to develop fast screening methods for PFAS partitioning. Calibration curves of different ranges were first evaluated in both water and Escherichia coli ( E. coli ) biomass matrix-matched samples. Stable isotope-labeled internal standard, 13 C 8 -PFOS, was used for both calibration curves and samples to enable quantification. E. coli suspensions were exposed to PFOS, and the resulting biomass was washed, added with internal standard, lysed, and directly deposited onto a MALDI target with 1,5-diaminonaphthalene as the MALDI matrix for analysis. Comparable, low-ppb (µg/L) limit of quantification was determined for calibration curves in water and biomass sample matrices. Using external calibration curves and isotopically labeled standards, we quantified the amount of PFOS associated with bacterial biomass and found that the partitioning is time- and dose-dependent. The workflow allowed direct detection of PFOS from processed bacterial biomass with significantly reduced sample preparation and instrumental analysis time, establishing MALDI-MS as a rapid and quantitative approach for PFAS analysis and providing a foundation for higher-throughput screening of PFAS across diverse biological samples.

ChemRxiv
Michigan State University (US)
Michigan State University, College of Engineering, Michigan State University
Per- and polyfluoroalkyl substances research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon