Out-of-Plane Stability Bearing Capacity of Concrete-Fileld Steel Tubular Double-Cross Columns: Calculation Method and Finite Element Verification

Concrete-filled steel tubular (CFST) double-cross columns are used in super-large cooling towers, but a method for calculating their out-of-plane stability bearing capacity is lacking. This study aims to develop and verify such a method. The inclined column was simplified as a two-span continuous compression member fixed at the base, hinged at the top, and elastically supported at the lower intersection point. An implicit characteristic equation was established using the singularity function method, and an explicit simplified formula was obtained by function fitting. Euler’s formula was used to back-calculate the effective length factor, and a calculation method for the out-of-plane stability bearing capacity was established according to GB 50936-2014. Finite element analysis was used to examine the axial force distribution and the effects of cross-sectional dimensions, material strength, intersection angle, lower intersection point position, and initial geometric imperfections; sensitivity analysis was also performed. The theoretical formulas for the out-of-plane stability bearing capacity of CFST double-cross columns were modified based on the finite element results. The relative errors of the implicit and explicit methods for the elastic stability bearing capacity of the continuous compression member were from 0.6% to 2.1% and from −10.7% to 8.2%, respectively. After modification, the relative errors of the theoretical elastoplastic stability bearing capacity of CFST double-cross columns ranged from −12% to 0%. The bearing capacity increased with cross-sectional dimensions and material strength, decreased with intersection angle and initial imperfections, and was slightly affected by the lower intersection point position. Concrete compressive strength and steel tube outer diameter were the most sensitive parameters. The proposed method provides a reference for engineering design.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-11-12
DOI
https://doi.org/10.3390/buildings16224511
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Out-of-Plane Stability Bearing Capacity of Concrete-Fileld Steel Tubular Double-Cross Columns: Calculation Method and Finite Element Verification

Xiaoxiong Zha, Kaichao Wang, Binbin Sun
Buildings
Structural Load-Bearing Analysis
article

Out-of-Plane Stability Bearing Capacity of Concrete-Fileld Steel Tubular Double-Cross Columns: Calculation Method and Finite Element Verification

Xiaoxiong Zha, Kaichao Wang, Binbin Sun
article en

Abstract

Concrete-filled steel tubular (CFST) double-cross columns are used in super-large cooling towers, but a method for calculating their out-of-plane stability bearing capacity is lacking. This study aims to develop and verify such a method. The inclined column was simplified as a two-span continuous compression member fixed at the base, hinged at the top, and elastically supported at the lower intersection point. An implicit characteristic equation was established using the singularity function method, and an explicit simplified formula was obtained by function fitting. Euler’s formula was used to back-calculate the effective length factor, and a calculation method for the out-of-plane stability bearing capacity was established according to GB 50936-2014. Finite element analysis was used to examine the axial force distribution and the effects of cross-sectional dimensions, material strength, intersection angle, lower intersection point position, and initial geometric imperfections; sensitivity analysis was also performed. The theoretical formulas for the out-of-plane stability bearing capacity of CFST double-cross columns were modified based on the finite element results. The relative errors of the implicit and explicit methods for the elastic stability bearing capacity of the continuous compression member were from 0.6% to 2.1% and from −10.7% to 8.2%, respectively. After modification, the relative errors of the theoretical elastoplastic stability bearing capacity of CFST double-cross columns ranged from −12% to 0%. The bearing capacity increased with cross-sectional dimensions and material strength, decreased with intersection angle and initial imperfections, and was slightly affected by the lower intersection point position. Concrete compressive strength and steel tube outer diameter were the most sensitive parameters. The proposed method provides a reference for engineering design.

BuildingsVol. 16(22)
Harbin Institute of Technology (CN)
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.