Operational Stability of Three Tooth Margin Preparation Instruments

ABSTRACT Objective: Achieving precise tooth margins is critical for restoration longevity and relies heavily on the clinician's tactile control of the instrument. However, objective, quantitative comparisons of operational stability among modern preparation instruments are lacking. This study aimed to quantitatively evaluate and compare the operational stability of three tooth margin preparation instruments by analyzing vertical force ( Fz ) characteristics under varying settings. Methods and Materials: The ultrasonic preparation device was tested across 10 power levels (groups S1-S10: 2-20 Watts, in 2-Watt increments), and the electric high-speed handpiece was evaluated at five rotational speeds (E1: 10,000 rpm, E2: 50,000 rpm, E3: 100,000 rpm, E4: 150,000 rpm, E5: 200,000 rpm). A turbine handpiece served as the control (group T). Each instrument was rigidly mounted to a multifunctional friction and wear tester via custom clamping collars and performed ten 10-second no-load test cycles. Vertical force ( Fz ) data from the stable operational phase (2-8 seconds) were analyzed. Welch's ANOVA and Dunnett's T3 post hoc tests were used for statistical comparisons (α = 0.05), with the standard deviation of Fz serving as the metric for operational stability. Results: The turbine handpiece (control) generated occlusally directed forces, whereas the electric and ultrasonic preparation devices produced gingivally directed forces. The maximum-power ultrasonic group (S10) showed the highest absolute Fz value (0.1573 ± 0.0290 N), while the maximum-speed electric handpiece (E5) showed the lowest (0.0201 ± 0.0120 N). Welch's ANOVA revealed significant differences between the control and the ultrasonic groups ( p < 0.0001), as well as between the control and the electric groups ( p = 0.0007). The turbine handpiece and high-power ultrasonic groups (S7-S10) exhibited significantly greater force variability (SD: 0.0237-0.0424 N) than the electric handpieces (SD: 0.0053-0.0120 N), indicating lower operational stability. Conclusions: The three tooth margin preparation instruments differed in vertical force direction and magnitude across different settings. The maximum-power ultrasonic preparation device generated the highest force, and the maximum-speed electric handpieces generated the lowest. Higher-power ultrasonic preparation devices and turbine handpieces showed poorer force stability, whereas electric high-speed handpieces maintained superior stability across all speeds.

Authors

Institutions

Publication Details

Journal
Operative Dentistry
Published
2026-11-12
DOI
https://doi.org/10.2341/25-113-l
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Operational Stability of Three Tooth Margin Preparation Instruments

T Luo, Y Shui, J Sun, H Yu
Operative Dentistry
Dental materials and restorations
article

Operational Stability of Three Tooth Margin Preparation Instruments

T Luo, Y Shui, J Sun, H Yu
article en

Abstract

ABSTRACT Objective: Achieving precise tooth margins is critical for restoration longevity and relies heavily on the clinician's tactile control of the instrument. However, objective, quantitative comparisons of operational stability among modern preparation instruments are lacking. This study aimed to quantitatively evaluate and compare the operational stability of three tooth margin preparation instruments by analyzing vertical force ( Fz ) characteristics under varying settings. Methods and Materials: The ultrasonic preparation device was tested across 10 power levels (groups S1-S10: 2-20 Watts, in 2-Watt increments), and the electric high-speed handpiece was evaluated at five rotational speeds (E1: 10,000 rpm, E2: 50,000 rpm, E3: 100,000 rpm, E4: 150,000 rpm, E5: 200,000 rpm). A turbine handpiece served as the control (group T). Each instrument was rigidly mounted to a multifunctional friction and wear tester via custom clamping collars and performed ten 10-second no-load test cycles. Vertical force ( Fz ) data from the stable operational phase (2-8 seconds) were analyzed. Welch's ANOVA and Dunnett's T3 post hoc tests were used for statistical comparisons (α = 0.05), with the standard deviation of Fz serving as the metric for operational stability. Results: The turbine handpiece (control) generated occlusally directed forces, whereas the electric and ultrasonic preparation devices produced gingivally directed forces. The maximum-power ultrasonic group (S10) showed the highest absolute Fz value (0.1573 ± 0.0290 N), while the maximum-speed electric handpiece (E5) showed the lowest (0.0201 ± 0.0120 N). Welch's ANOVA revealed significant differences between the control and the ultrasonic groups ( p < 0.0001), as well as between the control and the electric groups ( p = 0.0007). The turbine handpiece and high-power ultrasonic groups (S7-S10) exhibited significantly greater force variability (SD: 0.0237-0.0424 N) than the electric handpieces (SD: 0.0053-0.0120 N), indicating lower operational stability. Conclusions: The three tooth margin preparation instruments differed in vertical force direction and magnitude across different settings. The maximum-power ultrasonic preparation device generated the highest force, and the maximum-speed electric handpieces generated the lowest. Higher-power ultrasonic preparation devices and turbine handpieces showed poorer force stability, whereas electric high-speed handpieces maintained superior stability across all speeds.

Operative Dentistry
Sichuan University (CN), Stomatology Hospital (CN), State Key Laboratory of Oral Diseases (CN)
Good health and well-being
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon