Analysis of Corrosion Failure of the Positioning Sleeve of a Limit Positioner

Corrosion failure was investigated in the aluminum alloy positioning sleeve of a limit positioner used on a coastal railway line. Field inspection, optical microscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy, and bulk chemical composition analysis were used to characterize the failed component. The sleeve exhibited layered exfoliation at the surface and blocky spalling in the central corroded region. Microscopic observations revealed intergranular cracking and separation of corrosion layers. Sulfur was detected in the analyzed regions, whereas chlorine was detected in one region. The measured Cu content was 2.08 wt%, exceeding the 0.10 wt% upper limit specified for 6082 aluminum alloy in GB/T 3190–2008. These findings suggest that the failure was associated with the coastal corrosive environment and the nonconforming alloy composition. Pitting, intergranular corrosion, and exfoliation were identified as relevant forms of damage, with sea breeze and train-induced airflow potentially promoting the detachment of loosened material. Material composition control, routine inspection, and suitable surface protection are recommended to reduce similar failures in catenary components.

Authors

Institutions

Publication Details

Journal
Corrosion and Materials Degradation
Published
2026-11-12
DOI
https://doi.org/10.3390/cmd7040079
Primary Topic
Mechanical Failure Analysis and Simulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Analysis of Corrosion Failure of the Positioning Sleeve of a Limit Positioner

Yingxin Zhao, 张海波, Pingshen Qian, Qingyuan Zhao et al.
Corrosion and Materials Degradation
Mechanical Failure Analysis and Simulation
article

Analysis of Corrosion Failure of the Positioning Sleeve of a Limit Positioner

Yingxin Zhao, 张海波, Pingshen Qian, Qingyuan Zhao, Tong Xing, Wei Li
article en

Abstract

Corrosion failure was investigated in the aluminum alloy positioning sleeve of a limit positioner used on a coastal railway line. Field inspection, optical microscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy, and bulk chemical composition analysis were used to characterize the failed component. The sleeve exhibited layered exfoliation at the surface and blocky spalling in the central corroded region. Microscopic observations revealed intergranular cracking and separation of corrosion layers. Sulfur was detected in the analyzed regions, whereas chlorine was detected in one region. The measured Cu content was 2.08 wt%, exceeding the 0.10 wt% upper limit specified for 6082 aluminum alloy in GB/T 3190–2008. These findings suggest that the failure was associated with the coastal corrosive environment and the nonconforming alloy composition. Pitting, intergranular corrosion, and exfoliation were identified as relevant forms of damage, with sea breeze and train-induced airflow potentially promoting the detachment of loosened material. Material composition control, routine inspection, and suitable surface protection are recommended to reduce similar failures in catenary components.

Corrosion and Materials DegradationVol. 7(4)
China Academy of Railway Sciences (CN)
Mechanical Failure Analysis and Simulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon