MODELING AND CALCULATION OF ENVIRONMENTAL PROTECTI

District heating (DH) systems of multi-storey buildings include the following main elements: a heat source, heating networks and local consumption systems – heating, air conditioning (cooling) and hot water supply systems. The heat generating device (boiler room) produces heat and distributes it to the apartments on the floors. However, when natural gas is burned in the heat generating device (boiler room), harmful substances such as nitrogen dioxideand carbon dioxide are released into the environment. A modeling project and calculation of a ground-to-water geothermal heat pump for hot water supply, heating, and cooling of a ten-story, forty-apartment building as a replacement for a heat-generating device was made. Based on the results of the calculation, a new schematic diagram of the heat pump was developed, which provides centralized heating and cooling of a ten-story forty-apartment building. And decentralized apartment stations for the distribution and hygienic preparation of hot water are made on the basis of boilers. The analysis of literature sources made it possible to choose new equipment with the highest efficiency. Calculations confirmed the correctness of the choice of equipment type and materials for replacement. The obtained energy efficiency of the new thermal power plant is 93 % for this project, as well as its energy payback period is 3.8 years, and the use of a geothermal ground-water heat pump in the thermal power plant allows: – to reduce the cost of thermal energy by reducing material consumption and equipment costs, save organic fuel; produce thermal energy; reduce thermal load and environmental pollution.Calculation of cost savings after abandoning natural gas as an energy carrier for a heatgenerating device gave savings of UAH. Calculation of the amount of emissions of harmful substances during combustion of natural gas showed that abandoning natural gas as an energy carrier makes it possible not to emit 1341 tons/year of harmful substances into the environ-ment.

Authors

Institutions

Publication Details

Journal
Integrated Technologies and Energy Saving
Published
2026-11-12
DOI
https://doi.org/10.20998/2078-5364.2026.3.04
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

MODELING AND CALCULATION OF ENVIRONMENTAL PROTECTI

Tetyana Chernogor, Kostiantyn Gorbunov, Yurii Selikhov, Yehor Khrychov et al.
Integrated Technologies and Energy Saving
Geothermal Energy Systems and Applications
article

MODELING AND CALCULATION OF ENVIRONMENTAL PROTECTI

Tetyana Chernogor, Kostiantyn Gorbunov, Yurii Selikhov, Yehor Khrychov, Oleksandr Antonenko
article en

Abstract

District heating (DH) systems of multi-storey buildings include the following main elements: a heat source, heating networks and local consumption systems – heating, air conditioning (cooling) and hot water supply systems. The heat generating device (boiler room) produces heat and distributes it to the apartments on the floors. However, when natural gas is burned in the heat generating device (boiler room), harmful substances such as nitrogen dioxideand carbon dioxide are released into the environment. A modeling project and calculation of a ground-to-water geothermal heat pump for hot water supply, heating, and cooling of a ten-story, forty-apartment building as a replacement for a heat-generating device was made. Based on the results of the calculation, a new schematic diagram of the heat pump was developed, which provides centralized heating and cooling of a ten-story forty-apartment building. And decentralized apartment stations for the distribution and hygienic preparation of hot water are made on the basis of boilers. The analysis of literature sources made it possible to choose new equipment with the highest efficiency. Calculations confirmed the correctness of the choice of equipment type and materials for replacement. The obtained energy efficiency of the new thermal power plant is 93 % for this project, as well as its energy payback period is 3.8 years, and the use of a geothermal ground-water heat pump in the thermal power plant allows: – to reduce the cost of thermal energy by reducing material consumption and equipment costs, save organic fuel; produce thermal energy; reduce thermal load and environmental pollution.Calculation of cost savings after abandoning natural gas as an energy carrier for a heatgenerating device gave savings of UAH. Calculation of the amount of emissions of harmful substances during combustion of natural gas showed that abandoning natural gas as an energy carrier makes it possible not to emit 1341 tons/year of harmful substances into the environ-ment.

Integrated Technologies and Energy Saving(3)
National Technical University "Kharkiv Polytechnic Institute" (UA)
Affordable and clean energy, Climate action
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon