Experimental study of the performance of a water-to-water heat pump working with R744/R290 mixtures as refrigerant for low-to-medium ΔT applications

This study experimentally investigates a water-to-water heat pump operating with pure R744 and R744/R290 mixtures (0-20% propane) for low-to-medium Δ T applications, corresponding to water temperature increases of 5–20 K at the gas cooler. COP, heating capacity, and optimal gas cooler pressure are evaluated with and without internal heat exchanger (IHX). Three approaches are adopted: in the first, the refrigerant charge is fixed at the R744 reference value with the IHX active; in the second, the same charge is used with the IHX bypassed, which limits tests to propane fractions ≤ 10% due to superheat constraints; in the third, the charge is optimized for the 85/15% and 80/20% w mixtures to match the superheat of the pure R744 baseline. With the IHX active, high R290 fractions (15-20%) increase COP by up to 21.6% compared to pure R744. Without IHX and with R290 up to 10%, COP gains reach 7%, while under optimized charge the 85/15% mixture provides no significant improvement, whereas the 80/20% mixture improves COP. COP is consistently higher with the IHX, confirming its beneficial role. Heating capacity decreases with increasing propane content, by up to 12% at fixed charge and up to 26% when the charge is adjusted to maintain comparable superheat. In transcritical conditions the optimal gas cooler pressure decreases with increasing R290 fraction: up to 10% it follows a nearly linear trend related to the reduction in mixture critical pressure, whereas at higher fractions it approaches the mixture critical pressure, allowing subcritical or near-critical operation.

Authors

Institutions

Publication Details

Journal
International Journal of Refrigeration
Published
2026-11-12
DOI
https://doi.org/10.1016/j.ijrefrig.2026.107208
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Experimental study of the performance of a water-to-water heat pump working with R744/R290 mixtures as refrigerant for low-to-medium ΔT applications

Luca Molinaroli, Chiara D'Ignazi
International Journal of Refrigeration
Refrigeration and Air Conditioning Technologies
article

Experimental study of the performance of a water-to-water heat pump working with R744/R290 mixtures as refrigerant for low-to-medium ΔT applications

Luca Molinaroli, Chiara D'Ignazi
article en

Abstract

This study experimentally investigates a water-to-water heat pump operating with pure R744 and R744/R290 mixtures (0-20% propane) for low-to-medium Δ T applications, corresponding to water temperature increases of 5–20 K at the gas cooler. COP, heating capacity, and optimal gas cooler pressure are evaluated with and without internal heat exchanger (IHX). Three approaches are adopted: in the first, the refrigerant charge is fixed at the R744 reference value with the IHX active; in the second, the same charge is used with the IHX bypassed, which limits tests to propane fractions ≤ 10% due to superheat constraints; in the third, the charge is optimized for the 85/15% and 80/20% w mixtures to match the superheat of the pure R744 baseline. With the IHX active, high R290 fractions (15-20%) increase COP by up to 21.6% compared to pure R744. Without IHX and with R290 up to 10%, COP gains reach 7%, while under optimized charge the 85/15% mixture provides no significant improvement, whereas the 80/20% mixture improves COP. COP is consistently higher with the IHX, confirming its beneficial role. Heating capacity decreases with increasing propane content, by up to 12% at fixed charge and up to 26% when the charge is adjusted to maintain comparable superheat. In transcritical conditions the optimal gas cooler pressure decreases with increasing R290 fraction: up to 10% it follows a nearly linear trend related to the reduction in mixture critical pressure, whereas at higher fractions it approaches the mixture critical pressure, allowing subcritical or near-critical operation.

International Journal of RefrigerationVol. 193
Politecnico di Milano (IT)
Ministero dell’Istruzione, dell’Università e della Ricerca, Ministero dell'Istruzione e del Merito
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon