Combined Langmuir probe and collisional-radiative optical diagnostics of discharge conditions relevant to H - production in CeWNIS

Abstract The performance of surface-production negative-ion sources depends on the balance between H - production and competing loss processes. This balance depends on strongly coupled plasma parameters, including the electron density (n e ), electron temperature (T e ), electron energy probability function (EEPF), and hydrogen dissociation. The Cesiated Tungsten Dust-driven Negative Hydrogen Ion Source (CeWNIS) is a laboratory-scale facility under development for surface-assisted H - production. In this pre-beam commissioning study, the discharge characteristics of CeWNIS were investigated using combined Langmuir probe and optical emission spectroscopy (OES) diagnostics. The probe-measured non-Maxwellian EEPF was used as input to metastable-resolved collisional-radiative actinometry model. This connected the probe derived electron parameters to excitation sensitive optical line ratios. OES also provided the gas temperature and degree of hydrogen dissociation. The axial plasma density profile was used to select a practical operation separation of 80 mm between the multicusp magnetic cage and the dust coating unit (DCU). The selected configuration was then used to investigate the effect of working pressure. The degree of hydrogen dissociation decreased from 6.1±0.9% to 1.9±0.3% with increasing pressure. The measured plasma parameters were subsequently used as input to a particle balance model. Among the investigated pressures, the model predicted the highest steady-state H - density of (7.46±1.32)×10 15 m -3 near 1.5×10 -3 mbar. The study identifies a model based discharge condition window for subsequent H - production in CeWNIS.

Authors

Institutions

Publication Details

Journal
Physica Scripta
Published
2026-11-12
DOI
https://doi.org/10.1088/1402-4896/aec19d
Primary Topic
Low-Pressure Plasma Processing and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Combined Langmuir probe and collisional-radiative optical diagnostics of discharge conditions relevant to H - production in CeWNIS

SIDDHARTHA SANKAR KAUSIK, Bidyut Chutia, Jyotirmoy Goswami, Nipan Das et al.
Physica Scripta
Low-Pressure Plasma Processing and Diagnostics
article

Combined Langmuir probe and collisional-radiative optical diagnostics of discharge conditions relevant to H - production in CeWNIS

SIDDHARTHA SANKAR KAUSIK, Bidyut Chutia, Jyotirmoy Goswami, Nipan Das, B. K. Saikia, D. Goswami, Abhijit Roy
article en

Abstract

Abstract The performance of surface-production negative-ion sources depends on the balance between H - production and competing loss processes. This balance depends on strongly coupled plasma parameters, including the electron density (n e ), electron temperature (T e ), electron energy probability function (EEPF), and hydrogen dissociation. The Cesiated Tungsten Dust-driven Negative Hydrogen Ion Source (CeWNIS) is a laboratory-scale facility under development for surface-assisted H - production. In this pre-beam commissioning study, the discharge characteristics of CeWNIS were investigated using combined Langmuir probe and optical emission spectroscopy (OES) diagnostics. The probe-measured non-Maxwellian EEPF was used as input to metastable-resolved collisional-radiative actinometry model. This connected the probe derived electron parameters to excitation sensitive optical line ratios. OES also provided the gas temperature and degree of hydrogen dissociation. The axial plasma density profile was used to select a practical operation separation of 80 mm between the multicusp magnetic cage and the dust coating unit (DCU). The selected configuration was then used to investigate the effect of working pressure. The degree of hydrogen dissociation decreased from 6.1±0.9% to 1.9±0.3% with increasing pressure. The measured plasma parameters were subsequently used as input to a particle balance model. Among the investigated pressures, the model predicted the highest steady-state H - density of (7.46±1.32)×10 15 m -3 near 1.5×10 -3 mbar. The study identifies a model based discharge condition window for subsequent H - production in CeWNIS.

Physica Scripta
Institute for Plasma Research (IN), Centre of Plasma Physics - Institute for Plasma Research (IN)
Low-Pressure Plasma Processing and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon