All 3D-Printed Conducting Polymer Hydrogel-Based Soft Surface Electromyography Electrode Array for Noninvasive Fatigue Assessment

High-density surface electromyography (sEMG) electrode arrays allow the recording of rich myoelectric signals and provide a useful approach for monitoring exercise-induced muscle fatigue. However, existing sEMG electrode arrays often suffer from mechanical mismatches between conventional rigid electrodes and soft tissues, as well as complex fabrication processes and limited programmability, which severely constrain the rational design and practical application of sEMG electrode arrays. Herein, we successfully fabricate an eight-channel PEDOT:PSS-PVA hydrogel-based soft sEMG electrode array via a multi-material 3D printing. Through systematic rheological characterization of the composite inks and rational design of a printable three-layer electrode architecture, we achieve seamless interfacial integration and integrated sequential fabrication. The as-prepared sEMG electrode array exhibits exceptional softness comparable to that of human soft tissues (Young's modulus ∼ 10 kPa), low electrochemical impedance (∼22 Ω), and good electrochemical stability. Leveraging these advantageous properties, our sEMG electrode array enables noninvasive sEMG signal recording and monitoring of fatigue-associated sEMG changes with a high signal-to-noise ratio (SNR > 20 dB) under various grip forces before and after exercise, and captures sEMG changes associated with fatigue progression during repetitive movements. These results validate the capability of our electrode array for high-quality sEMG monitoring of fatigue-associated electrophysiological features and open up promising avenues for future applications such as scientific athletic training.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2026-11-12
DOI
https://doi.org/10.1021/acsami.6c14705
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

All 3D-Printed Conducting Polymer Hydrogel-Based Soft Surface Electromyography Electrode Array for Noninvasive Fatigue Assessment

Baoyang Lu, Tao Lin, Rongtai Wan, Yi He et al.
ACS Applied Materials & Interfaces
Advanced Sensor and Energy Harvesting Materials
article

All 3D-Printed Conducting Polymer Hydrogel-Based Soft Surface Electromyography Electrode Array for Noninvasive Fatigue Assessment

Baoyang Lu, Tao Lin, Rongtai Wan, Yi He, Bo Zhang, Gen Li, Jie Cao
article en

Abstract

High-density surface electromyography (sEMG) electrode arrays allow the recording of rich myoelectric signals and provide a useful approach for monitoring exercise-induced muscle fatigue. However, existing sEMG electrode arrays often suffer from mechanical mismatches between conventional rigid electrodes and soft tissues, as well as complex fabrication processes and limited programmability, which severely constrain the rational design and practical application of sEMG electrode arrays. Herein, we successfully fabricate an eight-channel PEDOT:PSS-PVA hydrogel-based soft sEMG electrode array via a multi-material 3D printing. Through systematic rheological characterization of the composite inks and rational design of a printable three-layer electrode architecture, we achieve seamless interfacial integration and integrated sequential fabrication. The as-prepared sEMG electrode array exhibits exceptional softness comparable to that of human soft tissues (Young's modulus ∼ 10 kPa), low electrochemical impedance (∼22 Ω), and good electrochemical stability. Leveraging these advantageous properties, our sEMG electrode array enables noninvasive sEMG signal recording and monitoring of fatigue-associated sEMG changes with a high signal-to-noise ratio (SNR > 20 dB) under various grip forces before and after exercise, and captures sEMG changes associated with fatigue progression during repetitive movements. These results validate the capability of our electrode array for high-quality sEMG monitoring of fatigue-associated electrophysiological features and open up promising avenues for future applications such as scientific athletic training.

ACS Applied Materials & Interfaces
Shandong University (CN), Shanghai Jiao Tong University (CN), Jiangxi Science and Technology Normal University (CN), Qilu Hospital of Shandong University (CN), Nanchang Jiaotong Institute (CN), Zhejiang University (CN)
National Natural Science Foundation of China
Good health and well-being
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon