One-Hour Diaphragmatic Thickening Fraction and the HACOR Score, Alone and Combined (HACOR-D), for Predicting Non-invasive Ventilation Failure in the Emergency Department
Abstract Background Non-invasive ventilation (NIV) is a cornerstone of management for acute respiratory distress in the emergency department, but failure requiring intubation remains common. The HACOR score is an established predictor of NIV failure and diaphragmatic thickening fraction (DTF) a promising one. This study aimed to determine, among patients who remained on NIV to the 1-hour landmark, whether HACOR provides incremental predictive value beyond DTF at 1 hour for subsequent NIV failure. Methods This secondary analysis used a prospective single-center cohort of adults with acute respiratory distress treated with NIV in an emergency department. Because DTF at 1 hour was a principal predictor, the analysis was landmarked at 1 hour and included only patients who remained on NIV to that reassessment; the model therefore estimates risk conditional on 1-hour NIV tolerance, not from the point of NIV initiation. HACOR was calculated at NIV initiation; DTF was measured at baseline and 1 hour. The primary outcome was NIV failure (endotracheal intubation) between 1 hour and 24 hours after NIV initiation. The primary comparison was the ΔAUC between DTF at 1 hour alone and a combined logistic model adding HACOR (HACOR-D). Bootstrap confidence intervals characterized uncertainty; likelihood-ratio testing assessed model fit. Results Among 126 patients, 36 (28.6%) experienced NIV failure. DTF at 1 hour had an AUC of 0.802 (95% CI 0.708 to 0.896), compared with 0.725 (95% CI 0.632 to 0.818) for HACOR. The combined model (HACOR-D) had an AUC of 0.812. The ΔAUC versus DTF at 1 hour alone was 0.010 (bootstrap 95% CI − 0.011 to 0.070; DeLong 95% CI − 0.028 to 0.048), with no significant improvement in discrimination. Adding HACOR significantly improved likelihood-based model fit (likelihood-ratio χ²=4.52; P = 0.033). Both retained statistically significant coefficients in the mutually adjusted model. Conclusions In patients who remained on NIV to the 1-hour landmark, DTF at 1 hour demonstrated an AUC of 0.802 for subsequent NIV failure, conditional on 1-hour NIV tolerance. Adding baseline HACOR (HACOR-D) significantly improved likelihood-based model fit but did not demonstrate additional AUC-based discrimination. The magnitude of any incremental benefit remains uncertain and requires validation in larger, multicenter cohorts.
Authors
- Sachin Nayak Sujir
- Vimal Krishnan S (ORCID: https://orcid.org/0000-0002-0100-2396)
- Pranav Prakash
- Mohammad KHALID
- Udit Umesh UMRANI
- Mohammed IMAAD KHATEEB
Institutions
- Manipal Academy of Higher Education (IN)
- M S Ramaiah University of Applied Sciences (IN)
- M.S. Ramaiah Medical College (IN)
- Kasturba Medical College, Manipal (IN)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-12
- DOI
- https://doi.org/10.21203/rs.3.rs-11245150/v1
- Primary Topic
- Respiratory Support and Mechanisms
- Type
- preprint
Funders
- Kasturba Medical College, Manipal