Produced-Fluid Analytics and Polymer Response During Alkali–Polymer Flooding After Polymer Flooding: Laboratory and Field Observations
Alkali–polymer (AP) flooding is a complex enhanced oil recovery (EOR) technique whose performance depends on reservoir mineralogy, crude oil properties, and formation water chemistry. The interactions among these factors can result in inconsistent field performance and make reliable prediction of AP breakthrough a key challenge for commercial applications. Accurate identification of breakthrough is particularly important because it directly influences operational decisions, including inhibitor dosing and production optimization. This study investigates the limitations of using pH as a standalone breakthrough indicator and proposes a multi-parameter analytical approach incorporating divalent cation concentrations, polymer concentration, alkalinity, and ammonia generation. As part of an Austrian AP flooding pilot project, laboratory core-flooding experiments were conducted under representative reservoir conditions. Two-phase flooding experiments were performed using 30-cm-long crude-oil-saturated core samples. The cores were sequentially injected with polymer and AP solutions to simulate field operations. Effluent samples were analyzed for iodide tracer concentration, sodium, calcium, magnesium, pH, alkalinity, ammonia, and polymer concentration. To evaluate the reproducibility of the results, duplicate experiments were conducted. In addition, a third experiment without polymer pre-flushing was performed to isolate AP breakthrough behavior. Field production data were subsequently analyzed to validate the laboratory observations. The results demonstrate that pH alone is insufficient for reliable assessment of AP breakthrough. Polymer concentrations in the effluent reached up to 1.9 times the injected concentration following AP injection into polymer-preconditioned cores, suggesting release of polymer retained during the preceding polymer flood. Alkali-induced desorption is considered a plausible mechanism; however, the present experiments do not independently distinguish desorption from other retention-release mechanisms. The laboratory experiments showed reproducible analytical response sequences, with Ca2+ decline preceding the main pH response under the investigated conditions. Comparison with selected pilot data showed qualitative consistency in the relative sequence of the principal indicators, although absolute timing differed between laboratory and field scales. The results support a multi-parameter framework for interpreting AP breakthrough while highlighting the limitations of using pH as a standalone indicator.
Authors
- Torsten Clemens (ORCID: https://orcid.org/0000-0002-9281-7557)
- Muhammad Tahir (ORCID: https://orcid.org/0000-0003-3819-9089)
- Dominik Steineder
- Amir Farzaneh (ORCID: https://orcid.org/0000-0002-4963-9767)
- Rafael Eduardo Hincapie (ORCID: https://orcid.org/0000-0003-1662-4064)
- Silvan Mikulic (ORCID: https://orcid.org/0000-0002-4245-5746)
- Johannes Schnöller
Publication Details
- Journal
- Polymers
- Published
- 2026-11-12
- DOI
- https://doi.org/10.3390/polym18222825
- Primary Topic
- Enhanced Oil Recovery Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00