DESIGN OF A STATIC DUAL-CHANNEL WIND CATCHER FOR AIR SUPPLY AND EXHAUST

The study presents a static dual-channel wind catcher designed to simultaneously supply fresh air and remove exhaust air without moving components. Analysis of existing wind catcher designs showed that most solutions focus primarily on air supply and provide limited separation of supply and exhaust flows. The proposed “pipe-in-pipe” configuration was developed based on an analysis of ventilation grille and deflector calculation methods, equal inlet and outlet cross-sectional areas, and two-dimensional numerical modelling using Energy2D. Numerical and experimental investigations confirmed the functionality of the proposed design and revealed an interdependent relationship between channel dimensions and wind catcher height. An empirical linear relationship was derived to determine the optimal channel diameter ratio depending on wind catcher height. The proposed solution can be applied in new construction and building renovation using existing ventilation ducts, reducing reliance on mechanical ventilation.

Authors

Institutions

Publication Details

Journal
Theory and Building Practice
Published
2026-11-12
DOI
https://doi.org/10.23939/jtbp2026.02.077
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

DESIGN OF A STATIC DUAL-CHANNEL WIND CATCHER FOR AIR SUPPLY AND EXHAUST

Yurii Furdas, Khrystyna Myroniuk, Vasyl Mizernyk, Volodymyr Burdyk
Theory and Building Practice
Wind and Air Flow Studies
article

DESIGN OF A STATIC DUAL-CHANNEL WIND CATCHER FOR AIR SUPPLY AND EXHAUST

Yurii Furdas, Khrystyna Myroniuk, Vasyl Mizernyk, Volodymyr Burdyk
article en

Abstract

The study presents a static dual-channel wind catcher designed to simultaneously supply fresh air and remove exhaust air without moving components. Analysis of existing wind catcher designs showed that most solutions focus primarily on air supply and provide limited separation of supply and exhaust flows. The proposed “pipe-in-pipe” configuration was developed based on an analysis of ventilation grille and deflector calculation methods, equal inlet and outlet cross-sectional areas, and two-dimensional numerical modelling using Energy2D. Numerical and experimental investigations confirmed the functionality of the proposed design and revealed an interdependent relationship between channel dimensions and wind catcher height. An empirical linear relationship was derived to determine the optimal channel diameter ratio depending on wind catcher height. The proposed solution can be applied in new construction and building renovation using existing ventilation ducts, reducing reliance on mechanical ventilation.

Theory and Building PracticeVol. 8(2)
Lviv Polytechnic National University (UA)
Affordable and clean energy
Wind and Air Flow Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon