Highly Reliable One-Pot SERS Aptasensor for Rapid Cardiac Troponin I Detection in Acute Myocardial Infarction

Rapid clinical decision-making for acute myocardial infarction (AMI) relies on the timely and precise assessment of cardiac biomarkers. However, detecting cardiac troponin I (cTnI), as the gold-standard biomarker for AMI, with both laboratory-grade sensitivity and rapid clinical turnaround remains a formidable challenge in point-of-care (POC) settings. To address this, we develop a one-pot surface-enhanced Raman scattering (SERS) aptasensor that integrates aptamer-mediated cTnI recognition, catalytic hairpin assembly (CHA) amplification, and plasmonic hotspot assembly. The assay supports two kinetic operating modes within the same assay: a 60-min high-sensitivity mode with a serum limit of detection (LOD) of 53.58 fg/mL and a 20-min rapid-triage mode with an LOD of 14.25 pg/mL, below the clinical decision threshold of 40 pg/mL. In a cohort of 100 clinical serum samples, the bootstrap optimism-corrected diagnostic accuracy was 91.3% for the SERS aptasensor, significantly outperforming conventional ELISA (77.8%). In a subset of 94 subjects with available routine cTnT results, the SERS-cTnI assay achieved an area under the receiver operating characteristic curve (AUC) of 0.988, comparable to that of the hospital's routine chemiluminescence cTnT assay (0.976), supporting its potential as a complementary diagnostic tool for cTnI-based AMI assessment. Furthermore, compatibility with a handheld Raman spectrometer was evaluated in an independent validation cohort (n = 36), achieving 97.2% accuracy using only 4 μL of serum within 20 min following serum preparation. This reliable one-pot SERS platform bridges ultra-sensitive detection and rapid portable readout, holding promise as a potential tool for future decentralized cardiovascular POC diagnostics.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2026-11-12
DOI
https://doi.org/10.1021/acssensors.6c03789
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Highly Reliable One-Pot SERS Aptasensor for Rapid Cardiac Troponin I Detection in Acute Myocardial Infarction

Chunyuan Song, Lan Wang, Lianhui Wang, Qian Peng et al.
ACS Sensors
Advanced biosensing and bioanalysis techniques
article

Highly Reliable One-Pot SERS Aptasensor for Rapid Cardiac Troponin I Detection in Acute Myocardial Infarction

Chunyuan Song, Lan Wang, Lianhui Wang, Qian Peng, Jingjing Zhang, Wei Sun, Xiyu He, Yongheng Li, Jian Liu
article en

Abstract

Rapid clinical decision-making for acute myocardial infarction (AMI) relies on the timely and precise assessment of cardiac biomarkers. However, detecting cardiac troponin I (cTnI), as the gold-standard biomarker for AMI, with both laboratory-grade sensitivity and rapid clinical turnaround remains a formidable challenge in point-of-care (POC) settings. To address this, we develop a one-pot surface-enhanced Raman scattering (SERS) aptasensor that integrates aptamer-mediated cTnI recognition, catalytic hairpin assembly (CHA) amplification, and plasmonic hotspot assembly. The assay supports two kinetic operating modes within the same assay: a 60-min high-sensitivity mode with a serum limit of detection (LOD) of 53.58 fg/mL and a 20-min rapid-triage mode with an LOD of 14.25 pg/mL, below the clinical decision threshold of 40 pg/mL. In a cohort of 100 clinical serum samples, the bootstrap optimism-corrected diagnostic accuracy was 91.3% for the SERS aptasensor, significantly outperforming conventional ELISA (77.8%). In a subset of 94 subjects with available routine cTnT results, the SERS-cTnI assay achieved an area under the receiver operating characteristic curve (AUC) of 0.988, comparable to that of the hospital's routine chemiluminescence cTnT assay (0.976), supporting its potential as a complementary diagnostic tool for cTnI-based AMI assessment. Furthermore, compatibility with a handheld Raman spectrometer was evaluated in an independent validation cohort (n = 36), achieving 97.2% accuracy using only 4 μL of serum within 20 min following serum preparation. This reliable one-pot SERS platform bridges ultra-sensitive detection and rapid portable readout, holding promise as a potential tool for future decentralized cardiovascular POC diagnostics.

ACS Sensors
Nanjing University of Posts and Telecommunications (CN), Jiangsu Province Hospital (CN), Nanjing Medical University (CN)
National Natural Science Foundation of China, Nanjing University of Posts and Telecommunications, Qinglan Project of Jiangsu Province of China
Good health and well-being
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon