Magneto-optical microimaging for hydrogen reaction on Fabry–Pérot cavity elements

Abstract Magneto-optical (MO) microimaging of hydrogen reactions on Fabry–Pérot cavity elements in a polar Kerr configuration was investigated. The MO cavity elements comprised surface half-mirror/MO interference layer/total-reflection mirror multilayers and hydrogen was detected via hydrogen reactions on the PdAu surface half-mirror. Kerr hysteresis measurements indicated MO polarity reversal via hydrogen absorption into the PdAu layer, which was theoretically attributed to MO resonance shifts. Additionally, distinct changes occurred in the MO microimages upon hydrogen exposure, which depended on the initial MO state and PdAu surface layer thickness. In the polar Kerr images, the regions of magnetization reversal appeared as dark lines under resonance conditions because the MO effect did not occur in these regions where the magnetization was optically zero. Furthermore, the hydrogen reaction reversed the magnetic domain contrast. This imaging technique possesses various chemical and biological applications if the surface half-mirror comprises suitable materials.

Authors

Institutions

Publication Details

Journal
Japanese Journal of Applied Physics
Published
2026-11-12
DOI
https://doi.org/10.35848/1347-4065/aec175
Primary Topic
Magneto-Optical Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Magneto-optical microimaging for hydrogen reaction on Fabry–Pérot cavity elements

Takashi Hasegawa, H. Yamane, Jiaxiang Liu
Japanese Journal of Applied Physics
Magneto-Optical Properties and Applications
article

Magneto-optical microimaging for hydrogen reaction on Fabry–Pérot cavity elements

Takashi Hasegawa, H. Yamane, Jiaxiang Liu
article en

Abstract

Abstract Magneto-optical (MO) microimaging of hydrogen reactions on Fabry–Pérot cavity elements in a polar Kerr configuration was investigated. The MO cavity elements comprised surface half-mirror/MO interference layer/total-reflection mirror multilayers and hydrogen was detected via hydrogen reactions on the PdAu surface half-mirror. Kerr hysteresis measurements indicated MO polarity reversal via hydrogen absorption into the PdAu layer, which was theoretically attributed to MO resonance shifts. Additionally, distinct changes occurred in the MO microimages upon hydrogen exposure, which depended on the initial MO state and PdAu surface layer thickness. In the polar Kerr images, the regions of magnetization reversal appeared as dark lines under resonance conditions because the MO effect did not occur in these regions where the magnetization was optically zero. Furthermore, the hydrogen reaction reversed the magnetic domain contrast. This imaging technique possesses various chemical and biological applications if the surface half-mirror comprises suitable materials.

Japanese Journal of Applied Physics
Akita University (JP), Akita Industrial Technology Center (JP)
Magneto-Optical Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon