Comparison of Prosthetic Valve Deformation and Hemodynamic Performance Between Bicuspid and Tricuspid Aortic Valve Anatomy After Transcatheter Aortic Valve Replacement

Background This study compared prosthetic valve deformation and postprocedural hemodynamic performance between bicuspid and tricuspid aortic valve anatomy after transcatheter aortic valve replacement with the Venus‐A prosthesis. Methods We retrospectively evaluated patients who underwent transcatheter aortic valve replacement between 2012 and 2022 and underwent postoperative computed tomography within 1 year. Predischarge echocardiographic assessments included the mean transvalvular gradient and paravalvular leak. Computed tomography measurements included expansion ratio, ellipticity, implantation depth, asymmetric leaflet expansion, and hypoattenuated leaflet thickening. The leaflet inflow and valve waist were collectively defined as the functional valve portion. Results Among 212 patients (106 bicuspid and 106 tricuspid), the mean age was 74.2±7.6 years, and 43.9% were women. Patients with bicuspid anatomy had a significantly lower oversizing ratio and underwent balloon predilation and postdilation more frequently than those with tricuspid anatomy. Residual transvalvular gradients were higher with bicuspid than tricuspid anatomy (12.0 [interquartile range, 8.2–17.0] versus 10.0 [7.2–14.0] mm Hg; P =0.014), whereas moderate to severe paravalvular leak did not differ significantly. Prosthetic ellipticity was greater in bicuspid anatomy, but expansion ratios, including those within the functional valve portion, did not differ significantly. Implantation depth, asymmetric leaflet expansion, and hypoattenuated leaflet thickening incidence also did not differ significantly. Conclusions Following Venus‐A implantation, bicuspid anatomy was associated with greater prosthetic ellipticity and higher residual gradients, despite no significant difference in prosthetic expansion.

Authors

Institutions

Publication Details

Journal
Journal of the American Heart Association
Published
2026-11-12
DOI
https://doi.org/10.1161/jaha.126.049690
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparison of Prosthetic Valve Deformation and Hemodynamic Performance Between Bicuspid and Tricuspid Aortic Valve Anatomy After Transcatheter Aortic Valve Replacement

Hongliang Zhang, Dejing Feng, Erli Zhang, Guannan Niu et al.
Journal of the American Heart Association
Cardiac Valve Diseases and Treatments
article

Comparison of Prosthetic Valve Deformation and Hemodynamic Performance Between Bicuspid and Tricuspid Aortic Valve Anatomy After Transcatheter Aortic Valve Replacement

Hongliang Zhang, Dejing Feng, Erli Zhang, Guannan Niu, Bin Zhang, Haowen Ma, Zhenyan Zhao, Yongjian Wu, Moyang Wang, Zhe Li, Zheng Zhou, Yunqing Ye, Jie Zhao
article en

Abstract

Background This study compared prosthetic valve deformation and postprocedural hemodynamic performance between bicuspid and tricuspid aortic valve anatomy after transcatheter aortic valve replacement with the Venus‐A prosthesis. Methods We retrospectively evaluated patients who underwent transcatheter aortic valve replacement between 2012 and 2022 and underwent postoperative computed tomography within 1 year. Predischarge echocardiographic assessments included the mean transvalvular gradient and paravalvular leak. Computed tomography measurements included expansion ratio, ellipticity, implantation depth, asymmetric leaflet expansion, and hypoattenuated leaflet thickening. The leaflet inflow and valve waist were collectively defined as the functional valve portion. Results Among 212 patients (106 bicuspid and 106 tricuspid), the mean age was 74.2±7.6 years, and 43.9% were women. Patients with bicuspid anatomy had a significantly lower oversizing ratio and underwent balloon predilation and postdilation more frequently than those with tricuspid anatomy. Residual transvalvular gradients were higher with bicuspid than tricuspid anatomy (12.0 [interquartile range, 8.2–17.0] versus 10.0 [7.2–14.0] mm Hg; P =0.014), whereas moderate to severe paravalvular leak did not differ significantly. Prosthetic ellipticity was greater in bicuspid anatomy, but expansion ratios, including those within the functional valve portion, did not differ significantly. Implantation depth, asymmetric leaflet expansion, and hypoattenuated leaflet thickening incidence also did not differ significantly. Conclusions Following Venus‐A implantation, bicuspid anatomy was associated with greater prosthetic ellipticity and higher residual gradients, despite no significant difference in prosthetic expansion.

Journal of the American Heart Association
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Fu Wai Hospital (CN)
Good health and well-being
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon