Cold-Adaptive Nanomotors Empowered by Robust Fluorescent Clusterzymes for Low-Temperature ATP Detection

The low-temperature environment is unfavorable for the dynamic movement of a probe in an aqueous medium, thereby restricting the analytical performance of conventional biosensing systems. To overcome this limitation, cold-adaptive probes that can withstand low temperatures have garnered significant interest recently. Herein, we report a new strategy for constructing cold-adaptive nanoprobes by exploiting fluorescent clusterzymes with enzyme-like catalytic properties to fabricate self-propelled nanomotors. Platinum nanoclusters (PtNCs) with distinct catalase-mimic properties and blue fluorescence are assembled onto asymmetric hollow silica nanobottles, yielding fluorescent nanomotors with markedly enhanced mobility fueled by H2O2 (0.983 μm2s-1), which is largely retained even at 0 °C (0.715 μm2s-1). A low-temperature sensing platform was further constructed by loading adenosine triphosphate (ATP)-responsive rhodamine dye onto the PtNC-based nanomotors. At 0 °C, the sensing system achieves a response time of 6 min and a detection limit of 0.072 mM, representing a less than 20% decrease in performance compared with room temperature (22 °C), which is adequate for low-temperature detection. Notably, compared with the static sensing counterpart, the self-propelled system exhibits an 83.3% improvement in response speed and a 69.6% reduction in detection limit, highlighting the significant advantages of the self-propelled design under low-temperature conditions. By integrating the probe into an anti-freezing hydrogel, a portable low-temperature sensing platform was constructed, enabling successful visual detection of ATP under cold conditions. This work establishes a new paradigm for low-temperature adaptive probe design by leveraging the unique properties of metal clusterzyme-based cold-adapted nanomotors.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2026-11-12
DOI
https://doi.org/10.1021/acssensors.6c03785
Primary Topic
Micro and Nano Robotics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Cold-Adaptive Nanomotors Empowered by Robust Fluorescent Clusterzymes for Low-Temperature ATP Detection

Yunshan Gao, Gao Ziyue, Li Shang, Wenfeng Liu et al.
ACS Sensors
Micro and Nano Robotics
article

Cold-Adaptive Nanomotors Empowered by Robust Fluorescent Clusterzymes for Low-Temperature ATP Detection

Yunshan Gao, Gao Ziyue, Li Shang, Wenfeng Liu, Gauhar Mussabek, Xiaomeng Zhou
article en

Abstract

The low-temperature environment is unfavorable for the dynamic movement of a probe in an aqueous medium, thereby restricting the analytical performance of conventional biosensing systems. To overcome this limitation, cold-adaptive probes that can withstand low temperatures have garnered significant interest recently. Herein, we report a new strategy for constructing cold-adaptive nanoprobes by exploiting fluorescent clusterzymes with enzyme-like catalytic properties to fabricate self-propelled nanomotors. Platinum nanoclusters (PtNCs) with distinct catalase-mimic properties and blue fluorescence are assembled onto asymmetric hollow silica nanobottles, yielding fluorescent nanomotors with markedly enhanced mobility fueled by H2O2 (0.983 μm2s-1), which is largely retained even at 0 °C (0.715 μm2s-1). A low-temperature sensing platform was further constructed by loading adenosine triphosphate (ATP)-responsive rhodamine dye onto the PtNC-based nanomotors. At 0 °C, the sensing system achieves a response time of 6 min and a detection limit of 0.072 mM, representing a less than 20% decrease in performance compared with room temperature (22 °C), which is adequate for low-temperature detection. Notably, compared with the static sensing counterpart, the self-propelled system exhibits an 83.3% improvement in response speed and a 69.6% reduction in detection limit, highlighting the significant advantages of the self-propelled design under low-temperature conditions. By integrating the probe into an anti-freezing hydrogel, a portable low-temperature sensing platform was constructed, enabling successful visual detection of ATP under cold conditions. This work establishes a new paradigm for low-temperature adaptive probe design by leveraging the unique properties of metal clusterzyme-based cold-adapted nanomotors.

ACS Sensors
Northwestern Polytechnical University (CN), Al-Farabi Kazakh National University (KZ)
National Natural Science Foundation of China, Ministry of Education of the People's Republic of China, Fundamental Research Funds for the Central Universities
Micro and Nano Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon