The Parity-Odd TB Spectrum Implied by a Uniform Rotation: A Cross-Check That Uses Temperature Instead of B-Mode Power

This paper examines what TB correlation a uniform rotation predicts, and whether TB offers an independent route to the same angle that does not depend on the much weaker B-mode signal in the same way EB does. The calculation is performed from stated assumptions and published polarisation measurements, using the deposited script so that every quoted number can be reproduced. The headline outputs are: beta deg = 0.30; TB uK2 = -0.314; mixing pct = 1.05; TE uK2 = -30.0. The treatment separates what the published measurements supply from what a theoretical framework must additionally provide; where a required quantity is not supplied, that absence is reported plainly as a negative result rather than replaced by an assumed value. The study is computed from stated assumptions and published inputs; it is not a new measurement. SIMULATED, NOT MEASURED in the sense that all derived quantities are calculated, not observed.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-12
DOI
https://doi.org/10.5281/zenodo.24168928
Primary Topic
Cosmology and Gravitation Theories
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The Parity-Odd TB Spectrum Implied by a Uniform Rotation: A Cross-Check That Uses Temperature Instead of B-Mode Power

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Cosmology and Gravitation Theories
article

The Parity-Odd TB Spectrum Implied by a Uniform Rotation: A Cross-Check That Uses Temperature Instead of B-Mode Power

William Alexander Aldred
article en

Abstract

This paper examines what TB correlation a uniform rotation predicts, and whether TB offers an independent route to the same angle that does not depend on the much weaker B-mode signal in the same way EB does. The calculation is performed from stated assumptions and published polarisation measurements, using the deposited script so that every quoted number can be reproduced. The headline outputs are: beta deg = 0.30; TB uK2 = -0.314; mixing pct = 1.05; TE uK2 = -30.0. The treatment separates what the published measurements supply from what a theoretical framework must additionally provide; where a required quantity is not supplied, that absence is reported plainly as a negative result rather than replaced by an assumed value. The study is computed from stated assumptions and published inputs; it is not a new measurement. SIMULATED, NOT MEASURED in the sense that all derived quantities are calculated, not observed.

Zenodo (CERN European Organization for Nuclear Research)
Cosmology and Gravitation Theories
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon