Automated Biomedical Waste Segregation Using Deep Learning: A Duplicate-Aware Classification Benchmark and Disposal-Safety Assessment

Improper segregation of biomedical waste allows infectious and otherwise hazardous material to enter general waste streams, with consequences for public health and the environment. Reliable automatic classification at the point of generation could support safer segregation and disposal. Deep learning has been applied to this task, but the public image datasets used for training and evaluation are commonly distributed in a pre-augmented form, in which each source photograph appears as many transformed copies. A conventional random train–test split then places near-identical copies in both sets, so the reported accuracy partly reflects memorisation rather than generalisation. We study automatic classification of 23 biomedical waste categories (15,600 background-removed images) with explicit attention to this issue. Because the dataset carries no ground-truth labelling of duplicates, a leakage-free partition cannot be certified; instead, visually near-identical images are grouped from image content using ORB keypoints with RANSAC geometric verification and kept within a single split, and this controlled estimate is compared against the fully mixed random split, which is known to be leaked, as an optimistic reference. Across four transfer-learning backbones, ConvNeXt-Tiny performs best, reaching a macro-F1 of 0.847±0.007 under the controlled split against 0.958±0.003 under the random split, so naive evaluation is optimistic by about eleven points. Mapping the categories onto World Health Organization hazard streams yields a disposal-bin accuracy of 0.892, with 1.76% of hazardous items misrouted to general waste. The study offers a benchmark and a more realistic basis for reporting automatic biomedical-waste classification.

Authors

Institutions

Publication Details

Journal
Polish Journal of Environmental Studies
Published
2026-11-12
DOI
https://doi.org/10.15244/pjoes/237574
Primary Topic
Healthcare and Environmental Waste Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Automated Biomedical Waste Segregation Using Deep Learning: A Duplicate-Aware Classification Benchmark and Disposal-Safety Assessment

Atakan Işık, Selin Işık
Polish Journal of Environmental Studies
Healthcare and Environmental Waste Management
article

Automated Biomedical Waste Segregation Using Deep Learning: A Duplicate-Aware Classification Benchmark and Disposal-Safety Assessment

Atakan Işık, Selin Işık
article en

Abstract

Improper segregation of biomedical waste allows infectious and otherwise hazardous material to enter general waste streams, with consequences for public health and the environment. Reliable automatic classification at the point of generation could support safer segregation and disposal. Deep learning has been applied to this task, but the public image datasets used for training and evaluation are commonly distributed in a pre-augmented form, in which each source photograph appears as many transformed copies. A conventional random train–test split then places near-identical copies in both sets, so the reported accuracy partly reflects memorisation rather than generalisation. We study automatic classification of 23 biomedical waste categories (15,600 background-removed images) with explicit attention to this issue. Because the dataset carries no ground-truth labelling of duplicates, a leakage-free partition cannot be certified; instead, visually near-identical images are grouped from image content using ORB keypoints with RANSAC geometric verification and kept within a single split, and this controlled estimate is compared against the fully mixed random split, which is known to be leaked, as an optimistic reference. Across four transfer-learning backbones, ConvNeXt-Tiny performs best, reaching a macro-F1 of 0.847±0.007 under the controlled split against 0.958±0.003 under the random split, so naive evaluation is optimistic by about eleven points. Mapping the categories onto World Health Organization hazard streams yields a disposal-bin accuracy of 0.892, with 1.76% of hazardous items misrouted to general waste. The study offers a benchmark and a more realistic basis for reporting automatic biomedical-waste classification.

Polish Journal of Environmental Studies
Başkent University (TR)
Responsible consumption and production, Good health and well-being
Healthcare and Environmental Waste Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon