Donor Site Evaluation Using Multispectral Optoacoustic Tomography in Patients with Head and Neck Cancer Who Require Free Flap Transplant Surgery

Head and neck cancer surgery requires autologous tissue transplants to reconstruct resection defects. The outcome of reconstructive surgery is often limited by perfusion-associated complications. To improve patient outcome, innovative approaches to detect perfusion deficits are essential for selecting the optimal free flap transplant donor site. Methods: A clinical pilot study was conducted that included 16 patients with head and neck cancer who were undergoing surgery and 10 healthy controls. Multispectral optoacoustic tomography (MSOT) was performed before surgery at the most common donor sites (radial forearm, latissimus dorsi, anterolateral thigh, and distal fibula). The biomarker of oxygen saturation in muscle and in the dermal layer was compared between healthy controls and patients and was correlated with clinical postsurgical outcomes. Results: MSOT examinations caused no adverse reactions and integrated smoothly into the clinical workflow. MSOT-derived muscle oxygen saturation showed significant differences between patients and healthy controls at all donor sites. These disparities became more pronounced under muscle provocation, revealing perfusion deficits that were previously not detected. Furthermore, exercise revealed side-to-side differences in hemoglobin saturation that exceeded 20%. Patients experiencing postoperative complications exhibited substantially reduced preoperative perfusion levels. Conclusion: In this clinical study, we demonstrated the feasibility of MSOT for donor site evaluation in autologous transplant surgery. Our findings highlight the potential of MSOT-derived hemoglobin metrics as functional imaging biomarkers for detection of perfusion deficits.

Authors

Institutions

Publication Details

Journal
Journal of Nuclear Medicine
Published
2026-11-12
DOI
https://doi.org/10.2967/jnumed.126.273209
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Donor Site Evaluation Using Multispectral Optoacoustic Tomography in Patients with Head and Neck Cancer Who Require Free Flap Transplant Surgery

Felix Wachter, Marco Rainer Kesting, Adrian Philip Regensburger, Ferdinand Knieling et al.
Journal of Nuclear Medicine
Photoacoustic and Ultrasonic Imaging
article

Donor Site Evaluation Using Multispectral Optoacoustic Tomography in Patients with Head and Neck Cancer Who Require Free Flap Transplant Surgery

Felix Wachter, Marco Rainer Kesting, Adrian Philip Regensburger, Ferdinand Knieling, Ulrich Rother, Moritz Schillinger, Manuel Weber, Lars‐Philip Paulus, Adrian Büehler, Joachim Wölfle, Briain Haney, Jonas V. Wolf, Christopher-Philipp Nobis
article en

Abstract

Head and neck cancer surgery requires autologous tissue transplants to reconstruct resection defects. The outcome of reconstructive surgery is often limited by perfusion-associated complications. To improve patient outcome, innovative approaches to detect perfusion deficits are essential for selecting the optimal free flap transplant donor site. Methods: A clinical pilot study was conducted that included 16 patients with head and neck cancer who were undergoing surgery and 10 healthy controls. Multispectral optoacoustic tomography (MSOT) was performed before surgery at the most common donor sites (radial forearm, latissimus dorsi, anterolateral thigh, and distal fibula). The biomarker of oxygen saturation in muscle and in the dermal layer was compared between healthy controls and patients and was correlated with clinical postsurgical outcomes. Results: MSOT examinations caused no adverse reactions and integrated smoothly into the clinical workflow. MSOT-derived muscle oxygen saturation showed significant differences between patients and healthy controls at all donor sites. These disparities became more pronounced under muscle provocation, revealing perfusion deficits that were previously not detected. Furthermore, exercise revealed side-to-side differences in hemoglobin saturation that exceeded 20%. Patients experiencing postoperative complications exhibited substantially reduced preoperative perfusion levels. Conclusion: In this clinical study, we demonstrated the feasibility of MSOT for donor site evaluation in autologous transplant surgery. Our findings highlight the potential of MSOT-derived hemoglobin metrics as functional imaging biomarkers for detection of perfusion deficits.

Journal of Nuclear Medicine
Friedrich-Alexander-Universität Erlangen-Nürnberg (DE), Universitätsklinikum Erlangen (DE)
Good health and well-being
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon