Objective Motion Analysis of Simulated Thoracoscopic Repair of Esophageal Atresia with Tracheoesophageal Fistula

Abstract Background Objective assessment of technical performance remains challenging in neonatal minimally invasive surgery. Instrument motion analysis may complement conventional assessment during simulation-based training. Objective To explore relationships among instrument motion parameters during simulated thoracoscopic repair of esophageal atresia with tracheoesophageal fistula and characterize patterns according to surgical experience and simulation model. Methods In this prospective observational study, 30 participants were stratified by surgical experience into experienced (n = 18) and inexperienced (n = 12) groups and randomly assigned to one of two synthetic esophageal atresia models. Following standardized video instruction, participants performed fistula closure and division, proximal pouch opening, and esophageal anastomosis within a 30-minute limit. The Laparo Analytic system continuously recorded instrument movements to quantify motion efficiency, smoothness, spatial utilization, and bimanual coordination. Spearman correlation analysis examined relationships among motion metrics within surgical experience and simulation model subgroups. Results Thirty participants were enrolled: 18 experienced and 12 inexperienced surgeons. Correlations were numerically stronger among experienced surgeons for economy of area versus path length (ρ = −0.98 versus − 0.79), depth perception versus economy of volume (ρ = −0.97 versus − 0.86), and clamp distance versus path length (ρ = 0.86 versus 0.71). Excessive acceleration correlated closely with hectic time in both groups (ρ = 0.98 and 0.96), whereas bimanual dexterity showed little association with path length (ρ = 0.13 and − 0.07). Strong inverse correlations between economy of volume and path length were observed with both models (ρ = −0.98 and − 0.94). Conclusion Motion analysis revealed interrelated spatial and kinematic parameters, with exploratory differences in correlation patterns according to surgical experience. These findings support further investigation of motion metrics as complementary assessment tools; their ability to discriminate proficiency requires validation in larger cohorts.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-12
DOI
https://doi.org/10.21203/rs.3.rs-11505558/v1
Primary Topic
Surgical Simulation and Training
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Objective Motion Analysis of Simulated Thoracoscopic Repair of Esophageal Atresia with Tracheoesophageal Fistula

Petra Zahradníková, Marta Kozuń, Stefan DURDIK, Ferdinand Varga et al.
Research Square
Surgical Simulation and Training
preprint

Objective Motion Analysis of Simulated Thoracoscopic Repair of Esophageal Atresia with Tracheoesophageal Fistula

Petra Zahradníková, Marta Kozuń, Stefan DURDIK, Ferdinand Varga, Jozef Babala, Silvia Hnilicová, Andrzej Więckowski, Marian Bakoš
preprint en

Abstract

Abstract Background Objective assessment of technical performance remains challenging in neonatal minimally invasive surgery. Instrument motion analysis may complement conventional assessment during simulation-based training. Objective To explore relationships among instrument motion parameters during simulated thoracoscopic repair of esophageal atresia with tracheoesophageal fistula and characterize patterns according to surgical experience and simulation model. Methods In this prospective observational study, 30 participants were stratified by surgical experience into experienced (n = 18) and inexperienced (n = 12) groups and randomly assigned to one of two synthetic esophageal atresia models. Following standardized video instruction, participants performed fistula closure and division, proximal pouch opening, and esophageal anastomosis within a 30-minute limit. The Laparo Analytic system continuously recorded instrument movements to quantify motion efficiency, smoothness, spatial utilization, and bimanual coordination. Spearman correlation analysis examined relationships among motion metrics within surgical experience and simulation model subgroups. Results Thirty participants were enrolled: 18 experienced and 12 inexperienced surgeons. Correlations were numerically stronger among experienced surgeons for economy of area versus path length (ρ = −0.98 versus − 0.79), depth perception versus economy of volume (ρ = −0.97 versus − 0.86), and clamp distance versus path length (ρ = 0.86 versus 0.71). Excessive acceleration correlated closely with hectic time in both groups (ρ = 0.98 and 0.96), whereas bimanual dexterity showed little association with path length (ρ = 0.13 and − 0.07). Strong inverse correlations between economy of volume and path length were observed with both models (ρ = −0.98 and − 0.94). Conclusion Motion analysis revealed interrelated spatial and kinematic parameters, with exploratory differences in correlation patterns according to surgical experience. These findings support further investigation of motion metrics as complementary assessment tools; their ability to discriminate proficiency requires validation in larger cohorts.

Research Square
Wrocław University of Science and Technology (PL), Masaryk University (CZ), Comenius University Bratislava (SK)
Good health and well-being
Surgical Simulation and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon