A primary study of inverted right-angle configuration cannulated screws fixation of femoral neck fracture based on elaborated 3-dimensional features of the femoral head and neck region

BACKGROUND: CT-based three-dimensional (3D) reconstruction was used to analyze the detailed anatomical morphology of the femoral head-neck region, and a modified inverted right-angle cannulated screw configuration was proposed to reduce the risk of posterosuperior screw in-out-in (IOI) placement during femoral neck fracture fixation. METHODS: Imaging data from 22 patients (12 males and 10 females; mean age, 52.5 ± 16.8 years) were retrospectively analyzed. CT data of both hips were imported into Mimics to construct 3D digital femoral models for morphologic analysis and screw trajectory simulation. Based on the observed anterior offset of the femoral head-neck canal and the sloped posterosuperior cortex of the femoral neck, a modified inverted right-angle screw configuration and a negative anteversion fluoroscopic view were proposed. Technical feasibility was preliminarily illustrated in two patients with femoral neck fractures. RESULTS: The femoral head-neck axis showed an anterior offset relative to the proximal femoral axis, which may increase the risk of posterosuperior IOI screw trajectory with the traditional inverted triangle configuration. In the 3D simulation, the modified inverted right-angle configuration placed the posterosuperior screw within the proposed safety zone. The negative anteversion fluoroscopic view appeared useful for identifying potential IOI screw trajectory. Technical feasibility of the proposed configuration was illustrated in two patients with femoral neck fractures, in whom no postoperative IOI screw displacement was observed on CT. CONCLUSION: The anatomical features of the femoral head-neck region may contribute to the risk of posterosuperior IOI screw trajectory with the traditional inverted triangle configuration. In this CT-based morphologic and simulation study, the modified inverted right-angle configuration showed a more favorable simulated position of the posterosuperior screw within the proposed safety zone, while negative anteversion fluoroscopy may help identify potential IOI screw trajectory. These preliminary findings require further validation through biomechanical studies and larger comparative clinical investigations.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-11-12
DOI
https://doi.org/10.1371/journal.pone.0361871
Primary Topic
Hip and Femur Fractures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A primary study of inverted right-angle configuration cannulated screws fixation of femoral neck fracture based on elaborated 3-dimensional features of the femoral head and neck region

Peihan Liu, Yang Hou, Han Zhang, Changjian Liu et al.
PLoS ONE
Hip and Femur Fractures
article

A primary study of inverted right-angle configuration cannulated screws fixation of femoral neck fracture based on elaborated 3-dimensional features of the femoral head and neck region

Peihan Liu, Yang Hou, Han Zhang, Changjian Liu, Yazhou Liu
article en

Abstract

BACKGROUND: CT-based three-dimensional (3D) reconstruction was used to analyze the detailed anatomical morphology of the femoral head-neck region, and a modified inverted right-angle cannulated screw configuration was proposed to reduce the risk of posterosuperior screw in-out-in (IOI) placement during femoral neck fracture fixation. METHODS: Imaging data from 22 patients (12 males and 10 females; mean age, 52.5 ± 16.8 years) were retrospectively analyzed. CT data of both hips were imported into Mimics to construct 3D digital femoral models for morphologic analysis and screw trajectory simulation. Based on the observed anterior offset of the femoral head-neck canal and the sloped posterosuperior cortex of the femoral neck, a modified inverted right-angle screw configuration and a negative anteversion fluoroscopic view were proposed. Technical feasibility was preliminarily illustrated in two patients with femoral neck fractures. RESULTS: The femoral head-neck axis showed an anterior offset relative to the proximal femoral axis, which may increase the risk of posterosuperior IOI screw trajectory with the traditional inverted triangle configuration. In the 3D simulation, the modified inverted right-angle configuration placed the posterosuperior screw within the proposed safety zone. The negative anteversion fluoroscopic view appeared useful for identifying potential IOI screw trajectory. Technical feasibility of the proposed configuration was illustrated in two patients with femoral neck fractures, in whom no postoperative IOI screw displacement was observed on CT. CONCLUSION: The anatomical features of the femoral head-neck region may contribute to the risk of posterosuperior IOI screw trajectory with the traditional inverted triangle configuration. In this CT-based morphologic and simulation study, the modified inverted right-angle configuration showed a more favorable simulated position of the posterosuperior screw within the proposed safety zone, while negative anteversion fluoroscopy may help identify potential IOI screw trajectory. These preliminary findings require further validation through biomechanical studies and larger comparative clinical investigations.

PLoS ONEVol. 21(11)
First Affiliated Hospital of Dalian Medical University (CN)
Good health and well-being
Hip and Femur Fractures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon