Technical Pearls and Solutions for All-Inside Anterior Cruciate Ligament (ACL) Reconstruction Using Quadriceps Tendon Autograft
Anterior cruciate ligament (ACL) reconstruction is one of the most common orthopaedic sports medicine procedures, with increasing interest in the quadriceps tendon (QT) autograft.Prior studies have detailed intraoperative pitfalls and management strategies for bone-patellar tendon-bone and hamstring tendon autograft ACL reconstructions.However, to our knowledge, there remains no comprehensive discussion of common intraoperative complications and technical challenges specific to the all-inside ACL reconstruction using QT autograft.The purpose of this study is to detail surgical technique and emphasize pearls and pitfalls associated with all-inside ACL reconstruction using QT autograft, focusing on graft harvesting, tunnel drilling, graft passage, and graft tensioning.Quadriceps tendon harvest utilizes a cylindrical cutter with proper trajectory from the superior pole of the patella to ensure adequate graft length (65-70 mm).Premature truncation below 60 mm may require allograft augmentation, while borderline graft length (60-64 mm) may warrant shorter femoral sockets (15-20 mm) to preserve adequate tibial fixation length.Full-thickness harvest sites are repaired with absorbable suture, creating a non-watertight closure for arthroscopic outflow.Graft-tunnel width mismatch is addressed through trimming for oversized grafts or allograft overlay for thin grafts.Anatomic femoral tunnel drilling selectively employs a low anteromedial portal with spinal needle guidance to protect the medial femoral condyle.Femoral socket preparation requires incremental drilling with frequent visualization to prevent posterior wall blowout.Tibial tunnel complications include flip cutter entrapment, soft tissue interposition at the cortex, sheath dislodgement, and tibial suture disruption, each requiring appropriate instrumentation and technique to prevent or address.Cortical suspensory fixation uses controlled tensioning to prevent button extrusion, with prophylactic notchplasty performed selectively based on intercondylar notch width and intraoperative assessment to prevent graft impingement.As QT autograft has become increasingly common in ACL reconstruction procedures, surgeons should familiarize themselves with the typical pitfalls that can arise during these cases and develop a clear understanding of management strategies.These strategies, based on the authors' surgical experience and the available literature, may be helpful to surgeons performing all-inside ACL reconstruction with QT autograft, although they have not been clinically validated.
Authors
- Christina Freiberger
- Michael Wilk
- Michael Letter
- Lee Kaplan
- Aziz Shittu
- Johann Braithwaite
Institutions
- University of Miami (US)
- McLaren Macomb (US)
Publication Details
- Journal
- Cureus
- Published
- 2026-11-12
- DOI
- https://doi.org/10.7759/cureus.119571
- Primary Topic
- Knee injuries and reconstruction techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00