Optomechatronic-optimized cell analysis: CPSA-SAM2 for precision segmentation in optical medical diagnostic systems

CPSA-SAM2 is an instance-segmentation model tailored to cell analysis in optomechatronic medical imaging, where speckle noise, a limited numerical aperture and real-time control loops constrain conventional networks. The model augments SAM2 with a positional attention module that encodes optical geometry and lens distortion, a semantic attention module that recalibrates channel responses, and low-rank adaptation for embedded deployment. On confocal and cytology sources rendered with physically grounded degradations it reaches a Dice coefficient of 0.9645 and a 95% Hausdorff distance of 4.87 pixels, generalises to real endoscopic and microscopy datasets, and sustains about 25 frames per second at 512×512, supporting closed-loop optical diagnosis.

Authors

Institutions

Publication Details

Journal
International Journal of Optomechatronics
Published
2026-11-12
DOI
https://doi.org/10.1080/15599612.2026.2735517
Primary Topic
Cell Image Analysis Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Optomechatronic-optimized cell analysis: CPSA-SAM2 for precision segmentation in optical medical diagnostic systems

Mingxin Liu, Dazhou Li, Xingyu Liu, Ziyan Yan et al.
International Journal of Optomechatronics
Cell Image Analysis Techniques
article

Optomechatronic-optimized cell analysis: CPSA-SAM2 for precision segmentation in optical medical diagnostic systems

Mingxin Liu, Dazhou Li, Xingyu Liu, Ziyan Yan, Jiabin Liang, Peilin Li
article en

Abstract

CPSA-SAM2 is an instance-segmentation model tailored to cell analysis in optomechatronic medical imaging, where speckle noise, a limited numerical aperture and real-time control loops constrain conventional networks. The model augments SAM2 with a positional attention module that encodes optical geometry and lens distortion, a semantic attention module that recalibrates channel responses, and low-rank adaptation for embedded deployment. On confocal and cytology sources rendered with physically grounded degradations it reaches a Dice coefficient of 0.9645 and a 95% Hausdorff distance of 4.87 pixels, generalises to real endoscopic and microscopy datasets, and sustains about 25 frames per second at 512×512, supporting closed-loop optical diagnosis.

International Journal of OptomechatronicsVol. 20(1)
Liaoning Provincial People's Hospital (CN), Shenyang University of Chemical Technology (CN)
Natural Science Foundation of Liaoning Province
Cell Image Analysis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon