Diagnostic Accuracy and Procedural Efficiency of ACR TI-RADS, EU-TIRADS, and K-TIRADS in ≤ 10 mm Thyroid Nodules Using Bethesda Cytology: A Cohort of 998 Nodules

OBJECTIVES: To compare the diagnostic performance and procedural efficiency of American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS), European Thyroid Imaging Reporting and Data System (EU-TIRADS), and Korean Thyroid Imaging Reporting and Data System (K-TIRADS) in ≤ 10 mm nodules using Bethesda cytology as the reference standard. METHODS: This retrospective study included 998 nodules ≤10 mm undergoing ultrasound-guided fine-needle aspiration biopsy (FNAB). Primary analyses included Bethesda II (negative) and Bethesda V-VI (positive) nodules excluding Bethesda I/III/IV, yielding 604 nodules (540 negative; 64 positive). Categories 1-3 were considered low risk and 4-5 high risk under a harmonized threshold Diagnostic performance and classification patterns were compared. RESULTS: K-TIRADS showed the numerically highest sensitivity (93.8%) and negative predictive value (NPV) (97.9%), although sensitivity did not differ significantly between systems, with lower specificity (35.4%) and accuracy (41.6%).EU-TIRADS showed intermediate performans (sensitivity 68.8%, specificity 73.7%, accuracy 73.2%). ACR TI-RADS achieved the highest specificity (83.3%) and accuracy (81.0%) with lower sensitivity (60.9%). Low-risk classification rates were 78.6% (ACR), 69.2% (EU), and 32.3% (K) of nodules; false-positive high-risk classifications among Bethesda II nodules were 16.7%, 26.3%, and 64.6%, respectively. CONCLUSION: In ≤ 10 mm nodules, the three systems demonstrated distinct diagnostic and classification profiles under a harmonized TR4-5 threshold, with different trade-offs between sensitivity and specificity. ADVANCES IN KNOWLEDGE: Applying a harmonized TR4-5 threshold in ≤ 10 mm nodules reveals substantially differences in classification patterns among the three systems, demonstrating that they are not interchangeable under a uniform risk threshold.

Authors

Institutions

Publication Details

Journal
British Journal of Radiology
Published
2026-11-12
DOI
https://doi.org/10.1093/bjr/tqag276
Primary Topic
Thyroid Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Diagnostic Accuracy and Procedural Efficiency of ACR TI-RADS, EU-TIRADS, and K-TIRADS in ≤ 10 mm Thyroid Nodules Using Bethesda Cytology: A Cohort of 998 Nodules

Aslan Oguz, Ebru Akay, Gamze Türk, Sinan Karatoprak et al.
British Journal of Radiology
Thyroid Cancer Diagnosis and Treatment
article

Diagnostic Accuracy and Procedural Efficiency of ACR TI-RADS, EU-TIRADS, and K-TIRADS in ≤ 10 mm Thyroid Nodules Using Bethesda Cytology: A Cohort of 998 Nodules

Aslan Oguz, Ebru Akay, Gamze Türk, Sinan Karatoprak, Mustafa Gökhan Bilgili
article en

Abstract

OBJECTIVES: To compare the diagnostic performance and procedural efficiency of American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS), European Thyroid Imaging Reporting and Data System (EU-TIRADS), and Korean Thyroid Imaging Reporting and Data System (K-TIRADS) in ≤ 10 mm nodules using Bethesda cytology as the reference standard. METHODS: This retrospective study included 998 nodules ≤10 mm undergoing ultrasound-guided fine-needle aspiration biopsy (FNAB). Primary analyses included Bethesda II (negative) and Bethesda V-VI (positive) nodules excluding Bethesda I/III/IV, yielding 604 nodules (540 negative; 64 positive). Categories 1-3 were considered low risk and 4-5 high risk under a harmonized threshold Diagnostic performance and classification patterns were compared. RESULTS: K-TIRADS showed the numerically highest sensitivity (93.8%) and negative predictive value (NPV) (97.9%), although sensitivity did not differ significantly between systems, with lower specificity (35.4%) and accuracy (41.6%).EU-TIRADS showed intermediate performans (sensitivity 68.8%, specificity 73.7%, accuracy 73.2%). ACR TI-RADS achieved the highest specificity (83.3%) and accuracy (81.0%) with lower sensitivity (60.9%). Low-risk classification rates were 78.6% (ACR), 69.2% (EU), and 32.3% (K) of nodules; false-positive high-risk classifications among Bethesda II nodules were 16.7%, 26.3%, and 64.6%, respectively. CONCLUSION: In ≤ 10 mm nodules, the three systems demonstrated distinct diagnostic and classification profiles under a harmonized TR4-5 threshold, with different trade-offs between sensitivity and specificity. ADVANCES IN KNOWLEDGE: Applying a harmonized TR4-5 threshold in ≤ 10 mm nodules reveals substantially differences in classification patterns among the three systems, demonstrating that they are not interchangeable under a uniform risk threshold.

British Journal of Radiology
Kayseri Eğitim ve Araştırma Hastanesi (TR)
Good health and well-being
Thyroid Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon