Design Blueprint: A Cavity-Enhanced Frequency-Comb Spectrometer Sized by Effective Path Length and Absorption Sensitivity

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24155217): This paper presents a computed design for a cavity-enhanced direct frequency-comb spectrometer covering a broad near-infrared band in a single acquisition. The sizing follows from applying the relevant intensity, thermal, nonlinear and geometric bounds at a single stated operating point, with every number produced by a deposited computation. The headline result is an effective absorption path of 12 km from a 0.60 m physical cavity, a finesse near 62830, a minimum detectable absorption coefficient of 8.3e-08 per metre per spectral element, and about 40000 spectral elements recorded in parallel Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-12
DOI
https://doi.org/10.5281/zenodo.24155647
Primary Topic
Spectroscopy and Laser Applications
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Design Blueprint: A Cavity-Enhanced Frequency-Comb Spectrometer Sized by Effective Path Length and Absorption Sensitivity

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Spectroscopy and Laser Applications
preprint

Design Blueprint: A Cavity-Enhanced Frequency-Comb Spectrometer Sized by Effective Path Length and Absorption Sensitivity

William Alexander Aldred
preprint en

Abstract

Design blueprint derived from the source paper (DOI 10.5281/zenodo.24155217): This paper presents a computed design for a cavity-enhanced direct frequency-comb spectrometer covering a broad near-infrared band in a single acquisition. The sizing follows from applying the relevant intensity, thermal, nonlinear and geometric bounds at a single stated operating point, with every number produced by a deposited computation. The headline result is an effective absorption path of 12 km from a 0.60 m physical cavity, a finesse near 62830, a minimum detectable absorption coefficient of 8.3e-08 per metre per spectral element, and about 40000 spectral elements recorded in parallel Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.

Zenodo (CERN European Organization for Nuclear Research)
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon