Dual-Functional Substrate-Integrated Accelerometer-Tactile Architecture for Absolute and Differential Motion Artifact Monitoring and Dual-Modality Arterial Pulse Measurement: Part II—Experimental Investigation

Background: A two-degree-of-freedom (2-DOF) formulation of the tissue-contact-sensor (TCS) stack in a substrate-integrated accelerometer (ACC)-tactile architecture provides a theoretical basis for complementary sensing of motion artifacts (MA), quantified as baseline drift (BD), and arterial pulse motion. Aim: This second of two parts experimentally investigates predicted relationships between tactile sensor and ACC outputs at the carotid artery (CA) and radial artery (RA) and complementary sensing characteristics. Methods: Using a micro/nano-fabricated tactile sensor integrated with a three-axis ACC attached to its substrate, arterial pulse signals were measured at the CA and RA in healthy subjects. A single-degree-of-freedom time-frequency (SDOF-TF) method analyzed tactile sensor and ACC outputs for BD, harmonic amplitudes, instantaneous frequency (IF), instantaneous initial phase (IIP), heart rate (HR), heart rate variability (HRV), respiration rate (RR), and respiration modulation (RM). Results: The tactile sensor provided cleaner arterial pulse signals than the z-axis ACC output and was relatively robust to MA. The absolute harmonic amplitudes of the ACC output were larger than those of the tactile sensor, consistent with the 2-DOF model, whereas normalized harmonic distributions relative to the first harmonic did not quantitatively reproduce the predicted frequency-dependent relationship, indicating measurement errors in the ACC output. Three-axis ACC measurements revealed radial, lateral, and axial components of arterial wall motion and MA. HR and RR were relatively consistent between outputs, whereas larger differences occurred in HRV and RM. Significance: This ACC-tactile architecture provides a framework for preliminary identification of relative relationships among TCS system parameters from complementary tactile and ACC measurements. The validated relative parameter relationships, together with the robustness of time-based indices to MA in the tactile output, provide a basis for deeper exploration of the model and tactile and ACC outputs for quantitative TCS parameter identification and TCS–artery interaction characterization at both arterial sites.

Authors

Publication Details

Journal
Preprints.org
Published
2026-11-12
DOI
https://doi.org/10.20944/preprints202611.1220.v1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Dual-Functional Substrate-Integrated Accelerometer-Tactile Architecture for Absolute and Differential Motion Artifact Monitoring and Dual-Modality Arterial Pulse Measurement: Part II—Experimental Investigation

Mamun Hasan, Zhili Hao
Preprints.org
Non-Invasive Vital Sign Monitoring
preprint

Dual-Functional Substrate-Integrated Accelerometer-Tactile Architecture for Absolute and Differential Motion Artifact Monitoring and Dual-Modality Arterial Pulse Measurement: Part II—Experimental Investigation

Mamun Hasan, Zhili Hao
preprint en

Abstract

Background: A two-degree-of-freedom (2-DOF) formulation of the tissue-contact-sensor (TCS) stack in a substrate-integrated accelerometer (ACC)-tactile architecture provides a theoretical basis for complementary sensing of motion artifacts (MA), quantified as baseline drift (BD), and arterial pulse motion. Aim: This second of two parts experimentally investigates predicted relationships between tactile sensor and ACC outputs at the carotid artery (CA) and radial artery (RA) and complementary sensing characteristics. Methods: Using a micro/nano-fabricated tactile sensor integrated with a three-axis ACC attached to its substrate, arterial pulse signals were measured at the CA and RA in healthy subjects. A single-degree-of-freedom time-frequency (SDOF-TF) method analyzed tactile sensor and ACC outputs for BD, harmonic amplitudes, instantaneous frequency (IF), instantaneous initial phase (IIP), heart rate (HR), heart rate variability (HRV), respiration rate (RR), and respiration modulation (RM). Results: The tactile sensor provided cleaner arterial pulse signals than the z-axis ACC output and was relatively robust to MA. The absolute harmonic amplitudes of the ACC output were larger than those of the tactile sensor, consistent with the 2-DOF model, whereas normalized harmonic distributions relative to the first harmonic did not quantitatively reproduce the predicted frequency-dependent relationship, indicating measurement errors in the ACC output. Three-axis ACC measurements revealed radial, lateral, and axial components of arterial wall motion and MA. HR and RR were relatively consistent between outputs, whereas larger differences occurred in HRV and RM. Significance: This ACC-tactile architecture provides a framework for preliminary identification of relative relationships among TCS system parameters from complementary tactile and ACC measurements. The validated relative parameter relationships, together with the robustness of time-based indices to MA in the tactile output, provide a basis for deeper exploration of the model and tactile and ACC outputs for quantitative TCS parameter identification and TCS–artery interaction characterization at both arterial sites.

Preprints.org
Good health and well-being
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon