Electric-Field-Driven Surface Ionic Transport on Hydroxylated SiO2 Governs Transient Leakage and Hybrid Bonding Reliability

Cu/SiO2 hybrid bonding is critical for 3D integrated circuit packaging, where dielectric surface activation impacts bonding quality and long-term reliability. NaOH-based wet chemical activation is a promising approach for a scalable and cost-effective processing under ambient conditions. However, this route introduces residual ions at the SiO2 surface, raising concerns regarding electrical leakage and dielectric stability. In this study, electric-field-driven surface ionic transport on NaOH-activated SiO2 and its role in transient leakage and hybrid bonding reliability were investigated. Reversible and polarity-dependent transient current peaks observed in cyclic electrical measurements provide evidence for electric-field-driven migration of the mobile ionic species at the SiO2 interface. In addition, higher NaOH concentrations promoted greater residual Na+ accumulation and intensified transient leakage peaks, supporting the selection of 0.5 M NaOH as an effective activation condition. Systematic decoupling experiments demonstrate that residual mobile Na+ ions are the dominant contributors to the transient leakage current rather than fixed hydroxyl groups. Quantitative analysis reveals Na+ surface mobility of approximately 3 × 10-10 m2V-1s-1, an order-of-magnitude upper-bound estimate that is consistent between constant-bias and ramped-bias measurements and about six orders of magnitude higher than that in bulk SiO2, suggesting a surface-dominated transport. An optimized 3 min deionized water (DI) rinse reduces the mobile Na+ population below the electrical detection limit and decreases the Na 1s XPS intensity by roughly an order of magnitude, suppressing the transient leakage to near-baseline levels while maintaining hydrophilicity and achieving the SiO2-SiO2 bonding strength of 19.7 ± 1.8 MPa, comparable to Ar plasma activation. The leakage measurements were performed on Cu/SiO2 damascene comb structures, whereas the bonding validation addresses the dielectric part of the hybrid-bonding interface; Cu-Cu contact and long-term stress testing remain to be verified. This work provides a framework for understanding electric-field-driven surface ionic transport and practical guidelines for contamination control of the dielectric surface in wet-activated Cu/SiO2 hybrid bonding.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2026-11-12
DOI
https://doi.org/10.1021/acsami.6c16637
Primary Topic
3D IC and TSV technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Electric-Field-Driven Surface Ionic Transport on Hydroxylated SiO2 Governs Transient Leakage and Hybrid Bonding Reliability

Wei-Lan Chiu, Chih Chen, Huai-En Lin, Yu-Xiang Huang et al.
ACS Applied Materials & Interfaces
3D IC and TSV technologies
article

Electric-Field-Driven Surface Ionic Transport on Hydroxylated SiO2 Governs Transient Leakage and Hybrid Bonding Reliability

Wei-Lan Chiu, Chih Chen, Huai-En Lin, Yu-Xiang Huang, Mai-Phuong La, Guann Pyng Li, Hsiang-Hung Chang
article en

Abstract

Cu/SiO2 hybrid bonding is critical for 3D integrated circuit packaging, where dielectric surface activation impacts bonding quality and long-term reliability. NaOH-based wet chemical activation is a promising approach for a scalable and cost-effective processing under ambient conditions. However, this route introduces residual ions at the SiO2 surface, raising concerns regarding electrical leakage and dielectric stability. In this study, electric-field-driven surface ionic transport on NaOH-activated SiO2 and its role in transient leakage and hybrid bonding reliability were investigated. Reversible and polarity-dependent transient current peaks observed in cyclic electrical measurements provide evidence for electric-field-driven migration of the mobile ionic species at the SiO2 interface. In addition, higher NaOH concentrations promoted greater residual Na+ accumulation and intensified transient leakage peaks, supporting the selection of 0.5 M NaOH as an effective activation condition. Systematic decoupling experiments demonstrate that residual mobile Na+ ions are the dominant contributors to the transient leakage current rather than fixed hydroxyl groups. Quantitative analysis reveals Na+ surface mobility of approximately 3 × 10-10 m2V-1s-1, an order-of-magnitude upper-bound estimate that is consistent between constant-bias and ramped-bias measurements and about six orders of magnitude higher than that in bulk SiO2, suggesting a surface-dominated transport. An optimized 3 min deionized water (DI) rinse reduces the mobile Na+ population below the electrical detection limit and decreases the Na 1s XPS intensity by roughly an order of magnitude, suppressing the transient leakage to near-baseline levels while maintaining hydrophilicity and achieving the SiO2-SiO2 bonding strength of 19.7 ± 1.8 MPa, comparable to Ar plasma activation. The leakage measurements were performed on Cu/SiO2 damascene comb structures, whereas the bonding validation addresses the dielectric part of the hybrid-bonding interface; Cu-Cu contact and long-term stress testing remain to be verified. This work provides a framework for understanding electric-field-driven surface ionic transport and practical guidelines for contamination control of the dielectric surface in wet-activated Cu/SiO2 hybrid bonding.

ACS Applied Materials & Interfaces
ITRI International (US), National Yang Ming Chiao Tung University (TW), University of California System (US), Industrial Technology Research Institute (TW)
National Science and Technology Council
3D IC and TSV technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon