Enceladus in Thermal Disequilibrium: Tidal Dissipation at the Present Eccentricity Against the Measured Heat Output

Enceladus radiates more heat than steady tidal dissipation at its present eccentricity comfortably supplies, and this study puts the shortfall in numbers. The standard dissipation formula with a dissipation factor k2 over Q of 0.01 gives 14.91 gigawatts, which barely matches the measured south polar output alone of 15.8 gigawatts and leaves nothing for conductive losses through the rest of the shell, whose global total has been estimated at 25 to 40 gigawatts. At a factor of 0.002 the supply is only 2.981 gigawatts. Only the generous factor of 0.05, yielding 74.53 gigawatts, covers the global estimates in steady state. Either the dissipation factor is at the high end, or Enceladus is spending heat stored during an earlier epoch, or dissipation in a porous rocky core contributes beyond the ice-shell term. Computed from stated assumptions, not measured.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-12
DOI
https://doi.org/10.5281/zenodo.24169080
Primary Topic
Astro and Planetary Science
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Enceladus in Thermal Disequilibrium: Tidal Dissipation at the Present Eccentricity Against the Measured Heat Output

William Alexander Aldred
Zenodo (CERN European Organization for Nuclear Research)
Astro and Planetary Science
article

Enceladus in Thermal Disequilibrium: Tidal Dissipation at the Present Eccentricity Against the Measured Heat Output

William Alexander Aldred
article en

Abstract

Enceladus radiates more heat than steady tidal dissipation at its present eccentricity comfortably supplies, and this study puts the shortfall in numbers. The standard dissipation formula with a dissipation factor k2 over Q of 0.01 gives 14.91 gigawatts, which barely matches the measured south polar output alone of 15.8 gigawatts and leaves nothing for conductive losses through the rest of the shell, whose global total has been estimated at 25 to 40 gigawatts. At a factor of 0.002 the supply is only 2.981 gigawatts. Only the generous factor of 0.05, yielding 74.53 gigawatts, covers the global estimates in steady state. Either the dissipation factor is at the high end, or Enceladus is spending heat stored during an earlier epoch, or dissipation in a porous rocky core contributes beyond the ice-shell term. Computed from stated assumptions, not measured.

Zenodo (CERN European Organization for Nuclear Research)
Astro and Planetary Science
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon