Volumetric Cross-Amplitude Modulation (VxAM) for Transcranial Gas Vesicle Imaging

Cross-amplitude modulation (xAM) is a commonly used pulse sequence for non-destructive, quasi-artifact-free detection of gas-vesicle (GV) contrast agents, but it has so far been limited to two-dimensional cross-sections acquired with one-dimensional linear arrays. We present the first implementation of xAM on a fully sampled two-dimensional matrix array, extending the half-aperture split of conventional xAM to a family of 2D sub-aperture partitions on a 32x32-element Vermon probe (7.81 MHz, 300 μm element pitch). Angular spectrum simulations compared three primary bisections (X-axis, Y-axis, and diagonal (D1,D2)), and the selected Y-split was tested experimentally in GV-loaded tissue-mimicking phantoms. We also simulated an electronic asymmetric-angle sweep as an alternative to the robotic translation used in the experiments, and measured contrast through an ex vivo mouse skull. The non-emissive regions between the elevation panels of the Vermon probe accounted for most of the simulated differences among partitions, through both the continuity of the aperture parallel to the bisector plane and the side-lobe structure. At a 6 degree steering angle, the Y-split gave a contrast-to-tissue ratio (CTR) of ~29 dB for single frames and ~49 dB with 100-frame averaging without the skull, and a contrast-to-noise ratio (CNR) of ~8 dB for single frames and ~12 dB with 100-frame averaging through the skull, where the inclusion remained resolvable. These results give design rules for xAM on matrix arrays. The through-skull result comes from a single ex vivo specimen, and in vivo work is the next step toward non-invasive, longitudinal, three-dimensional monitoring of GV-labeled glioblastoma and other targets of nonlinear contrast agents.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-11-12
DOI
https://doi.org/10.64898/2026.11.09.765388
Primary Topic
Ultrasound and Hyperthermia Applications
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Volumetric Cross-Amplitude Modulation (VxAM) for Transcranial Gas Vesicle Imaging

Hatim Belgharbi, Masashi Sode, Gianmarco Pinton, Andrew S. Weitz et al.
bioRxiv (Cold Spring Harbor Laboratory)
Ultrasound and Hyperthermia Applications
preprint

Volumetric Cross-Amplitude Modulation (VxAM) for Transcranial Gas Vesicle Imaging

Hatim Belgharbi, Masashi Sode, Gianmarco Pinton, Andrew S. Weitz, Rohit Nayak, Mikhail G. Shapiro, Paul A. Dayton, Trevor Fochtman, Rebecca M Jones-Sinnott
preprint en

Abstract

Cross-amplitude modulation (xAM) is a commonly used pulse sequence for non-destructive, quasi-artifact-free detection of gas-vesicle (GV) contrast agents, but it has so far been limited to two-dimensional cross-sections acquired with one-dimensional linear arrays. We present the first implementation of xAM on a fully sampled two-dimensional matrix array, extending the half-aperture split of conventional xAM to a family of 2D sub-aperture partitions on a 32x32-element Vermon probe (7.81 MHz, 300 μm element pitch). Angular spectrum simulations compared three primary bisections (X-axis, Y-axis, and diagonal (D1,D2)), and the selected Y-split was tested experimentally in GV-loaded tissue-mimicking phantoms. We also simulated an electronic asymmetric-angle sweep as an alternative to the robotic translation used in the experiments, and measured contrast through an ex vivo mouse skull. The non-emissive regions between the elevation panels of the Vermon probe accounted for most of the simulated differences among partitions, through both the continuity of the aperture parallel to the bisector plane and the side-lobe structure. At a 6 degree steering angle, the Y-split gave a contrast-to-tissue ratio (CTR) of ~29 dB for single frames and ~49 dB with 100-frame averaging without the skull, and a contrast-to-noise ratio (CNR) of ~8 dB for single frames and ~12 dB with 100-frame averaging through the skull, where the inclusion remained resolvable. These results give design rules for xAM on matrix arrays. The through-skull result comes from a single ex vivo specimen, and in vivo work is the next step toward non-invasive, longitudinal, three-dimensional monitoring of GV-labeled glioblastoma and other targets of nonlinear contrast agents.

bioRxiv (Cold Spring Harbor Laboratory)
University of North Carolina at Chapel Hill (US), California Institute of Technology (US)
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon