Geometric and Volumetric Changes Following Instrumentation with the One Curve and HyFlex EDM in Curved Root Canals: An In Vitro Micro-CT Study

Abstract Background The study aimed to evaluate shaping ability and dentin preservation capacity of two advanced heat-treated NiTi systems in the mesial canals of mandibular molars using micro-CT. Methods Forty mesial root canals of human mandibular molars with moderate curvatures were randomly assigned to two groups (each group: n = 20). The specimens were scanned using micro-CT before and after instrumentation with either the One Curve or HyFlex EDM system. Canal transportation, centering ability, the percentage of removed dentin volume, and minimum remaining dentin thickness were analyzed at 3, 5, 7, and 9 mm from the apex. Data were statistically analyzed using the independent samples t-test and the Mann-Whitney U test ( p < 0.05). Results Both file systems remained within the safe clinical threshold of 0.3 mm for canal transportation at all of the evaluated levels. At the 5-mm level (mid-root), the OC produced significantly less canal transportation compared to the HEDM ( p = 0.033). At the 9-mm level (pericervical dentin), the One Curve achieved a higher median minimum dentin thickness (1.090 vs. 0.737 mm for the HEDM), preserving this area more conservatively. A significant negative correlation was observed between transportation and centering ability across all levels for both groups ( p < 0.05). No significant differences were found between the systems regarding the percentage of removed dentin volume ( p > 0.05). Conclusion Within the limitations of this study, both systems demonstrated a high degree of shaping safety. However, the One Curve exhibited a more conservative instrumentation pattern at the mid-root and PCD, aligning more effectively with the principles of minimally invasive endodontics.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-12
DOI
https://doi.org/10.21203/rs.3.rs-11466860/v1
Primary Topic
Endodontics and Root Canal Treatments
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Geometric and Volumetric Changes Following Instrumentation with the One Curve and HyFlex EDM in Curved Root Canals: An In Vitro Micro-CT Study

Levent Akıncı, Neslihan Şımşek, Elçin Tekin Bulut
Research Square
Endodontics and Root Canal Treatments
preprint

Geometric and Volumetric Changes Following Instrumentation with the One Curve and HyFlex EDM in Curved Root Canals: An In Vitro Micro-CT Study

Levent Akıncı, Neslihan Şımşek, Elçin Tekin Bulut
preprint en

Abstract

Abstract Background The study aimed to evaluate shaping ability and dentin preservation capacity of two advanced heat-treated NiTi systems in the mesial canals of mandibular molars using micro-CT. Methods Forty mesial root canals of human mandibular molars with moderate curvatures were randomly assigned to two groups (each group: n = 20). The specimens were scanned using micro-CT before and after instrumentation with either the One Curve or HyFlex EDM system. Canal transportation, centering ability, the percentage of removed dentin volume, and minimum remaining dentin thickness were analyzed at 3, 5, 7, and 9 mm from the apex. Data were statistically analyzed using the independent samples t-test and the Mann-Whitney U test ( p < 0.05). Results Both file systems remained within the safe clinical threshold of 0.3 mm for canal transportation at all of the evaluated levels. At the 5-mm level (mid-root), the OC produced significantly less canal transportation compared to the HEDM ( p = 0.033). At the 9-mm level (pericervical dentin), the One Curve achieved a higher median minimum dentin thickness (1.090 vs. 0.737 mm for the HEDM), preserving this area more conservatively. A significant negative correlation was observed between transportation and centering ability across all levels for both groups ( p < 0.05). No significant differences were found between the systems regarding the percentage of removed dentin volume ( p > 0.05). Conclusion Within the limitations of this study, both systems demonstrated a high degree of shaping safety. However, the One Curve exhibited a more conservative instrumentation pattern at the mid-root and PCD, aligning more effectively with the principles of minimally invasive endodontics.

Research Square
Inonu University (TR), Usak University (TR)
Inönü Üniversitesi
Good health and well-being
Endodontics and Root Canal Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon