DEPI-MS: Density-Equalized Pseudo-Image Learning for Drift-Tolerant LC−MS Metabolomics Classification

Abstract Liquid chromatography−mass spectrometry (LC−MS)-based metabolomics captures system-level biochemical variation, but classification remains difficult under realistic acquisition variability. Conventional peak-table workflows reduce the continuous retention time (RT)−m/z intensity field to discrete features, thereby losing structural information such as peak morphology, co-elution patterns, and local background. Pseudo-image learning provides a way to preserve this signal field, yet current approaches often allocate image resolution inefficiently, rely on generic image backbones, and remain sensitive to chromatographic drift. Here, we present DEPI-MS, a Density-Equalized Pseudo-Image learning for LC-MS-based metabolomics. DEPI-MS combines three practical design choices tailored to LC−MS data. First, it preserves uniform RT binning while using QC-derived nonuniform m/z binning, assigning more pixels to signal-dense mass regions without disrupting chromatographic interpretation. Second, a compact multi-scale classifier aggregates local peak-like responses and broader RT−m/z context through channel-wise global feature reweighting. Third, differentiable RT-axis warping is applied during training to reduce sensitivity to smooth chromatographic displacement without regenerating pseudo-images from raw files. In a nasopharyngeal carcinoma serum cohort, DEPI-MS achieved an AUC of 0.984 on an independent external validation set and remained stable under a 60 s RT-drift stress test, outperforming representative peak-table and pseudo-image baselines. Cohort-level attribution further localized recurrent model evidence to RT−m/z regions, providing candidate signal loci for biochemical follow-up. These results support DEPI-MS as a practical route toward transferable LC−MS metabolomics classification under acquisition variability.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-11-12
DOI
https://doi.org/10.1021/acs.analchem.6c03243
Primary Topic
Metabolomics and Mass Spectrometry Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

DEPI-MS: Density-Equalized Pseudo-Image Learning for Drift-Tolerant LC−MS Metabolomics Classification

Jiyang Dong, Zhaodong Fei, Kian‐Kai Cheng, Daniel Raftery et al.
Analytical Chemistry
Metabolomics and Mass Spectrometry Studies
article

DEPI-MS: Density-Equalized Pseudo-Image Learning for Drift-Tolerant LC−MS Metabolomics Classification

Jiyang Dong, Zhaodong Fei, Kian‐Kai Cheng, Daniel Raftery, Xunhua Huang, Aihua Ye, Shuang Gao, 向楠 徐, Xiaohui Lin, Xiumei Gu, Jie Yang
article en

Abstract

Abstract Liquid chromatography−mass spectrometry (LC−MS)-based metabolomics captures system-level biochemical variation, but classification remains difficult under realistic acquisition variability. Conventional peak-table workflows reduce the continuous retention time (RT)−m/z intensity field to discrete features, thereby losing structural information such as peak morphology, co-elution patterns, and local background. Pseudo-image learning provides a way to preserve this signal field, yet current approaches often allocate image resolution inefficiently, rely on generic image backbones, and remain sensitive to chromatographic drift. Here, we present DEPI-MS, a Density-Equalized Pseudo-Image learning for LC-MS-based metabolomics. DEPI-MS combines three practical design choices tailored to LC−MS data. First, it preserves uniform RT binning while using QC-derived nonuniform m/z binning, assigning more pixels to signal-dense mass regions without disrupting chromatographic interpretation. Second, a compact multi-scale classifier aggregates local peak-like responses and broader RT−m/z context through channel-wise global feature reweighting. Third, differentiable RT-axis warping is applied during training to reduce sensitivity to smooth chromatographic displacement without regenerating pseudo-images from raw files. In a nasopharyngeal carcinoma serum cohort, DEPI-MS achieved an AUC of 0.984 on an independent external validation set and remained stable under a 60 s RT-drift stress test, outperforming representative peak-table and pseudo-image baselines. Cohort-level attribution further localized recurrent model evidence to RT−m/z regions, providing candidate signal loci for biochemical follow-up. These results support DEPI-MS as a practical route toward transferable LC−MS metabolomics classification under acquisition variability.

Analytical Chemistry
The University of Sydney (AU), Fujian Medical University (CN), Zhejiang Normal University (CN), Xiamen University (CN), University of Washington (US), First Affiliated Hospital of Fujian Medical University (CN), Fujian Provincial Cancer Hospital (CN), University of Technology Malaysia (MY)
National Natural Science Foundation of China, Natural Science Foundation of Fujian Province
Metabolomics and Mass Spectrometry Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon