NUMERICAL MODELING AND STRUCTURAL ANALYSIS OF A MODULAR REINFORCED CONCRETE SHELTER

This study presents numerical modelling and structural assessment of a modular prefabricated reinforced concrete shelter. The initial configuration with 160 mm walls was compared with a modernized design using 330 mm C25/30 concrete walls. Regulations in Ukraine and five European countries were reviewed to contextualize thickness requirements. Structural checks under equivalent quasi-static blast-wave loading were performed in accordance with Ukrainian standards and Eurocode 2 using IDEA StatiCa. The 160 mm design showed insufficient bearing capacity, whereas the 330 mm configuration satisfied the adopted strength criteria. Although increased thickness reduced the calculated reinforcement demand, minimum code-prescribed detailing must be maintained. Further verification is needed for precast joints, local penetration, concrete spalling and dynamic blast response.

Authors

Institutions

Publication Details

Journal
Theory and Building Practice
Published
2026-11-12
DOI
https://doi.org/10.23939/jtbp2026.02.176
Primary Topic
Structural Response to Dynamic Loads
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

NUMERICAL MODELING AND STRUCTURAL ANALYSIS OF A MODULAR REINFORCED CONCRETE SHELTER

Iryna Grynyova, Oleg Fesenko, Vladyslav Shekhovtsov, Yevhenii Klymenko
Theory and Building Practice
Structural Response to Dynamic Loads
article

NUMERICAL MODELING AND STRUCTURAL ANALYSIS OF A MODULAR REINFORCED CONCRETE SHELTER

Iryna Grynyova, Oleg Fesenko, Vladyslav Shekhovtsov, Yevhenii Klymenko
article en

Abstract

This study presents numerical modelling and structural assessment of a modular prefabricated reinforced concrete shelter. The initial configuration with 160 mm walls was compared with a modernized design using 330 mm C25/30 concrete walls. Regulations in Ukraine and five European countries were reviewed to contextualize thickness requirements. Structural checks under equivalent quasi-static blast-wave loading were performed in accordance with Ukrainian standards and Eurocode 2 using IDEA StatiCa. The 160 mm design showed insufficient bearing capacity, whereas the 330 mm configuration satisfied the adopted strength criteria. Although increased thickness reduced the calculated reinforcement demand, minimum code-prescribed detailing must be maintained. Further verification is needed for precast joints, local penetration, concrete spalling and dynamic blast response.

Theory and Building PracticeVol. 8(2)
Odessa State Academy of Civil Engineering and Architecture (UA)
Industry, innovation and infrastructure
Structural Response to Dynamic Loads
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon