ANALISIS KONDISI PIPA PRIMARY SUPERHEATER BOILER MENGGUNAKAN ULTRASONIC THICKNESS

The integrity of superheater tubes is critical to the reliability and operational safety of steam boilers in thermal power plants. This study assesses the condition of the Primary Superheater Flue Gas Outlet of Boiler Unit #51 at PT Amman Mineral Nusa Tenggara using Ultrasonic Thickness Measurement (UTM) data from September 2024 and April 2026. A total of 32 tubes were evaluated using descriptive statistics, paired t-test, Pearson correlation, and Measurement System Analysis (MSA). The results showed that the average tube thickness increased from 6.332 to 6.449 mm, with a statistically significant difference between the two inspection periods (p < 0.001). However, the low Pearson correlation coefficient (r = 0.1633) indicated weak correspondence between measurements. The MSA yielded a Mean Error of 0.1166 mm, RMSE of 0.1368 mm, and Coefficient of Variation values of 0.97% and 0.78% for 2024 and 2026, respectively. These results indicate good measurement precision but reveal a systematic positive bias that should be considered when interpreting thickness changes. No significant wall thinning or localized degradation was identified. Therefore, the Primary Superheater Flue Gas Outlet remains in a serviceable condition. Integrating statistical analysis with MSA provides a more reliable basis for interpreting UTM results and supporting condition-based maintenance decisions.

Authors

Institutions

Publication Details

Journal
Energy Materials and Product Design
Published
2026-11-11
DOI
https://doi.org/10.29303/empd.v5n2.455-462
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

ANALISIS KONDISI PIPA PRIMARY SUPERHEATER BOILER MENGGUNAKAN ULTRASONIC THICKNESS

I Made Mara, I Wayan Joniarta, I Made Adi Sayoga
Energy Materials and Product Design
Non-Destructive Testing Techniques
article

ANALISIS KONDISI PIPA PRIMARY SUPERHEATER BOILER MENGGUNAKAN ULTRASONIC THICKNESS

I Made Mara, I Wayan Joniarta, I Made Adi Sayoga
article en

Abstract

The integrity of superheater tubes is critical to the reliability and operational safety of steam boilers in thermal power plants. This study assesses the condition of the Primary Superheater Flue Gas Outlet of Boiler Unit #51 at PT Amman Mineral Nusa Tenggara using Ultrasonic Thickness Measurement (UTM) data from September 2024 and April 2026. A total of 32 tubes were evaluated using descriptive statistics, paired t-test, Pearson correlation, and Measurement System Analysis (MSA). The results showed that the average tube thickness increased from 6.332 to 6.449 mm, with a statistically significant difference between the two inspection periods (p < 0.001). However, the low Pearson correlation coefficient (r = 0.1633) indicated weak correspondence between measurements. The MSA yielded a Mean Error of 0.1166 mm, RMSE of 0.1368 mm, and Coefficient of Variation values of 0.97% and 0.78% for 2024 and 2026, respectively. These results indicate good measurement precision but reveal a systematic positive bias that should be considered when interpreting thickness changes. No significant wall thinning or localized degradation was identified. Therefore, the Primary Superheater Flue Gas Outlet remains in a serviceable condition. Integrating statistical analysis with MSA provides a more reliable basis for interpreting UTM results and supporting condition-based maintenance decisions.

Energy Materials and Product DesignVol. 5(2)
University of Mataram (ID)
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon